Bennett Site Master Instruction Manual
Installation
5
INSTALLATION
Examine the shipment immediately upon arrival to make certain there has been no damage or loss in transit. Bennett Pump Company, as
shipper, is not liable for the hazards of transportation. Please make damage claims directly to the truck line.
Please read these instructions carefully and read all tags attached to the Site Master before starting installation. A Site Master Payment
Terminal that is not properly installed will not perform properly and will void the limited warranty. All other equipment manufacture’s
installation instructions must be followed. Bennett Pump does not provide other manufacture’s installation instructions and are not
responsible for any potential problems.
Installation must be in accordance with the
National Fire Protection Agency NFPA 70: National Electrical Code (NEC), NFPA 30A: Code for
Motor Fuel Dispensing Facilities and Repair Garages, NFPA 30: Flammable and Combustible Liquids Code, International Fire Code (IFC),
and all state and local codes.
SPECIFICATIONS
DIMENSIONS
Refer to Footprint Diagram (125927 – P4208) located inside the Site Master or on the USB provided.
Site Master Series Maximum .................................................................................................... 19
25
/
32
” (width) x 12 ¼” (depth) x 42” (height)
Site Master Series Estimated Shipping Weight ...........................................................................................................130 pounds/59 kilograms
POWER REQUIREMENTS
DANGER: INCOMING AC POWER AT TS1 OF THE TIMER BOARD WILL REMAIN ACTIVE IF THE MAIN CIRCUIT BREAKER(S) ARE
NOT TURNED OFF.
WARNING: TO PREVENT ELECTRIC SHOCK, MAKE SURE THE CURRENT IS OFF AT THE CIRCUIT BREAKER(S) AND THE BREAKER IS
LOCKED OUT BEFORE DOING ANY REPAIRS OR MAINTENANCE TO THE DISPENSER.
CAUTION:
THE INTRINSIC SAFETY GROUND WIRE MUST BE FIRMLY
AC Power Input, Electronic ................................................................................................................. 120/240 VAC, 50/60 Hz. 350 Watts Max.
DC Power Supply Output ........................................................................................................................................ +12 VDC at 2.00 Amps Max.
+24 VDC at 2.00 Amps Max.
Lead-Acid Battery Output .......................................................................................................................................... +12 VDC at 2.0 Amp Max.
Nickel-Cadmium Battery Output ....................................................................................................................... +3.6 VDC at 250 Milliamp Max.
ENVIRONMENTAL REQUIREMENTS
Operating Temperature Range ....................................................................................................................... -40°C to +65°C (-40°F to +149°F)
Humidity ........................................................................................................................................................................ 0-95% non-condensin
g
RECOMMENDED MATERIAL S
Note
:
Any Site Master must only use Underwriters (U.L) Listed equipment.
Anchor Bolts
Lifting device to lift and transport the Site Master.
Personal Barriers
Potting Compound
National Fire Protection Agency NFPA 70: National Electrical Code (NEC)
approved.
Static Straps
Multi-Meter