02.10.2020
Electrical limit values
Parameters
min.
max.
Unit
Operating voltage 12V
+11.8
+13
V
Operating voltage 5V
+4.5
+5.5
V
Power consumption (without external consumers)
0.05
0.4
W
Ambient temperature
0
+50
°C
Level for logical 0 at inputs
-0.3
+0.8
V
Level for logical 1 at inputs
2.0
5.5
V
Level at analog output
0
10.5
V
Switching capacity relay at 28VDC (TÜV rating)
-
6
A
Switching capacity relay at 28VDC (TÜV rating)
-
6
A
Dimensions
Description
Width
Length
Height
Unit
Overall dimensions
42
43
20
mm