Parameter Configuration

 

To meet the need of different customers, parameters can be set by yourselves. Parameters, 

such as data format, frame rate could be changed by sending command. Parameter will be stored 
in flash after configured successfully and customers don’t need to configure again when restart. 

Please  change  the  parameter  according  to  certain  demands  and  do  not  frequently  try 

irrelevant instructions. Please configure the product according to the demands of the manual and 
never send unstated command

TF02-Pro-W-485  supports  9600,  14400,  19200,  38400,  43000,  57600,  76800, 

115200 

(default)

,  128000,  230400,  256000,  460800,  921600,  1382,400  baudrate.  Considering  the 

reliability of communication, it is not recommended to use the baudrate above 115200. The default 
slave ID is 0x01. 

Note: Repower is required after configuration. 

Table 4 General Parameter Configuration and Description (Slave ID is 0x01)

 

Function 

Command 

Response 

Remark 

Read distance 

01 03 00 00 00 01 84 0A 

01 03 02 DH DL CL CH 

DH: 8 high-order bits of distance 

DL: 8 low-order bits of distance 

CH: 8 high-order bits of CRC 

CL: 8 low-order bits of CRC 

Read distance and 

signal strength 

01 03 00 00 00 02 C4 0B 

01 03 04 DH DL SH SL 

CL CH 

DH: 8 high-order bits of distance 

DL: 8 low-order bits of distance 

SH: 8 high-order bits of signal strength 

SL: 8 low-order bits of signal strength 

Read firmware version 

01 03 00 06 00 02 24 0A 

01 03 04 00 VM VS VC 

CL CH 

The software version is VM.VS.VC 

Set Baudrate 

01 06 00 83 BH1 BH2 CL 

CH 

01 06 00 84 BL1 BL2 CL 

CH 

01 06 00 83 BH1 BH2 CL 

CH 

01 06 00 84 BL1 BL2 CL 

CH 

For example, set baudrate to 9600 

(0x00002580) 

BH1=00 BH2=00 CL=78 CH=22 

BL1=25 BL2=80 CL=D2 CH=D3 

Set Slave ID 

01 06 00 85 IH IL CL CH 

01 06 00 84 IH IL CL CH 

For example,

 

set slave ID to 0x02, IH=00 IL=02 

CL=19 CH=E2 

Set frame rate 

01 06 00 86 FH FL CL CH 

01 06 00 86 FH FL CL 

CH 

Set frame rate to 100 (0x0064), 

FH=00 FL=64 CL=69 CH=C8 

Save settings 

01 06 00 80 00 00 88 22 

01 06 00 80 00 00 88 22 

Repower to take effect 

Start the wiper 

01 06 00 8A 00 00 A8 20 

01 06 00 8A 00 00 A8 20 

Use this command to start the wiper at any time 

Modified dust removal 

cycle 

01 06 00 8C PH PL CL CH 

01 06 00 8C PH PL CL 

CH 

For example, making wiper works every 240 

minutes, PH=00 PL=F0 CL=48 CH=65 

Modify the number of 

wiper round trip 

01 06 00 8D WH WL CL 

CH 

01 06 00 8D WH WL CL 

CH 

The number should between 1 and 10. 

For example, wipe twice each time 

WH=00 WL=02 CL=98 CH=20 

 

Содержание TF02-Pro-W-485

Страница 1: ...Benewake Beijing CO Ltd Page1 SJ PM TF02 Pro W 485 A00 Product Manual TF02 Pro W 485 Product Manual...

Страница 2: ...Haidian District Beijing PRC Copyright The Copyright of this document is protected All the rights involved herein belong to Benewake Beijing Co Ltd Any copy activity of this document no matter in who...

Страница 3: ...n manual covers the product operation introduction and common problem solutions but it is really hard to covers all the problems you maybe meet So if you have any further questions or problems please...

Страница 4: ...ut this Manual 5 1 2 Usage of Product 5 1 3 Conditions with Potential Malfunction 5 2 Physical Interface 6 2 1 Description about Line Sequence 6 2 2 Electrical Characteristics 6 3 Appearance and Struc...

Страница 5: ...product is 20 C 60 C please do not use it beyond this temperature range so as to avoid risks The storage temperature of the product is 30 C 80 C please do not store it beyond this temperature range s...

Страница 6: ...ity protection so please make sure that connection and power supply are normal Table 2 Major Electrical Parameters Description Parameter value Supply voltage 7 30V Average current 200mA 12V Peak curre...

Страница 7: ...of electrical appliance dust proof and preventing the intrusion of foreign objects and the second representing degree of electrical appliance moisture proof and water proof The greater the number is t...

Страница 8: ...dust removal operation is driven by the LiDAR servo the wiper swing back and forth for 1 times In addition customer can control the LiDAR immediately by sending command for dust removal and modify the...

Страница 9: ...CRC CL 8 low order bits of CRC Read distance and signal strength 01 03 00 00 00 02 C4 0B 01 03 04 DH DL SH SL CL CH DH 8 high order bits of distance DL 8 low order bits of distance SH 8 high order bi...

Страница 10: ...matter Q2 How long is the life of product A2 The warranty period is 1 year and can be used for more than 3 years under normal circumstances the life of servo is larger than the product itself the life...

Отзывы: