TF03 UART/CAN Product Manual V1.2.2
Benewake(Beijing)Co., Ltd
Interface of configuration software is shown above.
1)
After TF03 is connected to the computer, select the correct serial port number and baud
rate in Zone C manually and click the
『
Connect
』
button to establish communication
between the software and TF03.
2)
After communication is established successfully, zone B will display the distance and
frequency of data. When no data is received over two seconds, the distance and
frequency display will disappear.
3)
Zone D is dedicated to function configuration and its third column lists the buttons for
sending instructions. After clicking such buttons, the configuration software will send
commands and wait for reply from TF03. When no reply is received for a long time,
『
No
Response
』
will be displayed on the right side of the instruction-sending buttons. Please
note that in order to ensure that TF03 reply instructions can be obtained normally, lower
the
『
frame rate
』
or set the
『
output mode
』
as
『
instruction trigger
』
before configuration.
If the changed parameters need to be saved, click
『
Save Configuration
』
before power
down TF03.
4)
Zone E is dedicated to firmware upgrade, BootLoader can be used to upgrade the
firmware.
7
Failure reasons and troubleshooting
1
)
Under normal operation, TF03 sometimes will output 18000(cm).
Reasons
:
The actual distance measured is beyond the range of TF03, TF03 will output 18000.
Troubleshooting
:
Treat 18000 as an exception value. When you receive 18000 from TF03,
don't adopt this data.
2
)
No data output after TF03 is connected to the TF display application.
Reason
Ⅰ:
The computer uses and operating system other than Windows.
Troubleshooting
:
Currently, the TF display application can only support the Windows
operating system. Use a computer with the Windows system installed.
Reason
Ⅱ:
Poor connection between TF03 and computer.
Please confirm that TF03 is correctly and reliably connected to the
computer, and ensure that the cables and adapter board work properly.