197837 RCD-2
Index C
121
9.2 OPERATION OF THE LPG SYSTEM
- Valves for supply lines and cylinder valves must be closed when appliances are not in use, before changing a cylinder and immediately in case of emergency.
- Appliance valves must be closed before opening the cylinder valve.
- Ventilation is necessary when appliances that consume oxygen from inside the boat are used.
- If the stove is not suspended by gimbals, it should not be used when wide roll angles or continuous listing are likely.
- Please refer to the manufacturer's notes for the use and maintenance of the LPG cooker.
9.3 VERIFICATION OF THE LPG SYSTEM
The LP system should be tested for leakage before each use in any of the following ways:
- If the LPG circuit is equipped with a pressure gauge:
Before each use, close the appliance valve, open the LPG cylinder valve, allow the pressure gauge to stabilize, close the LPG cylinder valve and observe the
pressure indicated by the pressure gauge near the LPG cylinder for 3 minutes. The pressure indicated by the manometer should be constant if there is no leak in
the system.
The pressure indicated by the manometer should be constant if there is no leak in the system. If bubbles are observed in the detector liquid, there is a leak.
NOTE: The pressure gauge only indicates vapour pressure, which is a constant at a given temperature. It gives no indication of the amount of LPG
remaining in the cylinder..
- Carry out a manual search by applying a foaming solution, soapy water or a detergent (with the burner taps closed and the installation and gas bottle taps left open). Foaming
solutions for detecting leaks in gas installations conforming to EN 14291 are adequate for these requirements.
- If the LPG circuit is equipped with a bubble leak detector, use it as follows:
Regularly observe the bubble leak detector.
OR
Once the installation is pressurised and stabilised, press the detector push button. The installation is not leaking if bubbles do not
appear in the detector liquid. If bubbles are observed in the detector liquid, there is a leak.
Liquef
ied Pet
roleum
G
as system (LPG)
9
Содержание 461
Страница 1: ...197837 RCD 2 Index C OCEANIS 46 1 OWNER S MANUAL ...
Страница 2: ......
Страница 4: ......
Страница 8: ......
Страница 17: ...17 STABILITY AND BUOYANCY Stability information 18 Access to the boat 20 3 ...
Страница 22: ...22 197837 RCD 2 Index C Access to companionway Holding Stability and buoyancy ...
Страница 24: ......
Страница 25: ...25 MANOEUVRABILITY Visibility from the steering station 26 4 ...
Страница 28: ......
Страница 62: ......
Страница 72: ......
Страница 93: ...197837 RCD 2 Index C 93 LAYOUT OF COMPONENTS Electrical system 8 ...
Страница 118: ...118 197837 RCD 2 Index C ...
Страница 125: ...125 DOMESTIC APPLIANCES Fridge Cooler 126 Water cooled refrigeration unit 128 Microwave 130 Dishwasher 131 10 10 ...
Страница 127: ...197837 RCD 2 Index C 127 The control is located directly inside the device Fridge Cooler Domestic appliances 10 10 ...
Страница 132: ......
Страница 133: ...133 AUDIO VISUAL EQUIPMENT Television 134 HiFi 135 11 11 ...
Страница 136: ......
Страница 145: ...197837 RCD 2 Index C 145 DIAGRAM OF LAYOUT Onboard comfort 12 12 ...
Страница 156: ......
Страница 202: ......
Страница 215: ...215 STEERING SYSTEM General points 216 Diagram of layout 217 Bow thruster stern thruster retractable 220 15 15 ...
Страница 217: ...197837 RCD 2 Index C 217 15 2 DIAGRAM OF LAYOUT Steering system 15 15 ...
Страница 218: ...218 197837 RCD 2 Index C View A Detail B Steering system ...
Страница 222: ...222 197837 RCD 2 Index C 1 Mounting screw 2 Anode Steering system ...
Страница 235: ...235 HULL FITTINGS Interior upholstery 236 Interior woodwork 239 Interior maintenance 240 17 17 ...
Страница 248: ......
Страница 249: ...249 ENVIRONMENT Waste management 250 19 19 ...
Страница 251: ...251 APPENDIX Label key 252 ...
Страница 254: ......