TWIG CONFIGURATOR
28
-
Enabled_no menu
: Verticality sensor is enabled
and the sensor state options are not available
in the phone’s quick menu.
•
Polling interval
: Polling interval determines the
rate at which the status of the sensor is checked
when it is in normal mode i.e. no alert is ongo-
ing. The interval can be set to 1-65535 seconds.
The default value is 10 seconds.
•
No alarm duration
:
When the sensor notices
alarm-triggering status (vertical/horizontal by
definition), this setting defines a period during
which the sensor is waiting for the normal status
to be restored, before actually triggering the
alarm. This is useful to prevent unnecessary
alarms e.g. in cases where the user has fallen
down but is able to get up quickly. The no alarm
period can be set to
1
-
65535
seconds. The
default value is
30
seconds.
•
Pre-alarm duration
: Once Verticality sensor has
noticed an alarm-triggering orientation and the
no alarm period has passed, the sensor enters
into pre-alarm period. During this state the sen-
sor is alarming the user by using the defined
sound and volume settings. When pre-alarm
period is over, and normal orientation is not
restored, the sensor launches Twig SOS applica-
tion. The pre-alarm period can be set to
1
-
65535
seconds. The default value is
30
seconds.
•
Normal status delay
: Normal status delay defines
a period which the sensor needs to be back in
the normal orientation before normal status is
actually restored. The normal status delay period
is useful to prevent restoring the normal status
and cancelling Twig SOS alert by accident. The
normal status delay can be set
1
-
65535
seconds.
The default value is
1
second.