7
2.3 CONTROL FUNCTIONS
AC Circuit Breakers
While the generator is running, the breakers should be put in the ON
position.
If the current has exceeded its limits it will automatically pop out to the
OFF position. Reduce the electrical load on the generator and push the
button back to the ON position.
Battery Charging Port
When the generator will be stored for an extended period of time plug
the battery charger into a 120V outlet every two months to top up the
battery and prolong its life.
Battery Power Switch
Disconnects the circuit to the electric start battery to reduce battery
drain while not in use.
DC Circuit Breakers
The DC circuit breaker automatically shuts off when the charging circuit
is overloaded.
If the current has exceeded its limits the breaker will automatically pop
out to the OFF position. Reduce the electrical load on the generator and
push the button back to the ON position.
Hour Meter
Display shows total run time. Use this to perform maintenance at the
proper intervals according to the ‘Maintenance Schedule’ section of this
manual.
EcoMode (Economy Control Switch)
Turning EcoMode to ON is recommended for minimizing fuel
consumption. In this mode the engine will dynamically meet the demand
of the current electrical load and will automatically go into an idle state if
all electrical loads are disconnected.
Before connecting or removing a high load device to the generator, turn
EcoMode to OFF until that device has reached running power.
When EcoMode is OFF, the engine runs at full speed.