background image

 

 

may occur to the finish.   
 

Technical Specification 

·

 

Supply: 220-240V~ 50Hz   

·

 

Rated power: 1800-2000W   

·

 

Lighting: LEDs

 

 

General Information 
 

Item 

Symbol  Value 

Unit  Item 

Unit 

Heat output 

Type  of  heat  input,  for  electric  storage  local  space  heaters 

only (select one) 

Nominal heat output

 

P

nom

 

1.9 

KW 

manual 

heat 

charge 

control, 

with 

integrated thermostat

 

 

Not applicable

 

Minimum 

heat 

output 

(indicative)

 

P

min

 

0.95 

KW 

manual  heat  charge  control  with  room 

and/or outdoor temperature feedback

 

Not applicable

 

Maximum  continuous  heat 

output

 

P

max

,

c

 

1.9 

KW 

electronic  heat  charge  control  with  room 

and/or outdoor temperature feedback

 

Not applicable

 

Auxiliary electricity consumption 

fan assisted heat output

 

Not applicable

 

At nominal heat output

 

el

max

 

0.014 

KW 

Type of heat output/room temperature control (select one) 

At minimum heat output

 

el

min

 

0.014 

KW 

single  stage  heat  output  and  no  room 

temperature control

 

[no]

 

In standby mode

 

el

SB

 

0.48 

Two  or  more  manual  stages,  no  room 

temperature control

 

[no]

 

 

with 

mechanic 

thermostat 

room 

temperature control

 

[no]

 

 

with electronic room temperature control

 

[no]

 

 

electronic  room  temperature  control  plus 

day timer

 

[no]

 

 

electronic  room  temperature  control  plus 

week timer

 

[yes]

 

 

Other control options (multiple selections possible) 

 

room temperature control, with    presence 

detection

 

[no]

 

 

room 

temperature 

control, 

with                 

open window detection

 

[no]

 

 

with distance control option

 

[no]

 

 

with adaptive start control

 

[yes]

 

 

with working time limitation

 

[no]

 

 

with black bulb sensor

 

[no]

 

Contact details

 

BE MODERN GROUP 

19/34 BEDESWAY,BEDE INDUSTRIAL EST 

JARROW, TYNE AND WEAR NE32 3BE

 

 
 

Содержание 2599MS

Страница 1: ...INSTALLATION AND USER INSTRUCTION GUIDE 2kW Electric Inset Fire with Remote Control Model 2599R 2599MS Read these instructions thoroughly before use and keep for future reference ...

Страница 2: ...sting fireplace that is prone to dampness Should it be necessary to cap and seal the chimney to prevent personal injury a professional should be hired to do the work This heater must be used on an AC supply only and the voltage marked on the heater must correspond to the supply voltage Do not switch the appliance on until it is properly installed as described in this manual The heater must not be ...

Страница 3: ... knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Cleaning and user maintenance shall not be made by children without supervision Children of less than 3 years should be kept away unless continuously supervised Children aged from 3 years and less than 8 years shall only switch on off the appliance provide...

Страница 4: ...Some parts of this product can become very hot and cause burns Particular attention has to be given where children and vulnerable people are present Installation Requirements Do not connect the heater to the mains power supply until all of the instructions have been read and the heater has been properly and securely fitted The minimum safe distances must be observed This heater must not be directl...

Страница 5: ...s and leave approximately 2mm gap see diagram below Lift the heater up to the hearth and slide the heater onto the two fixing screws Flat Wall Installation With spacer Spacer is an optional extra 53mm 018376 105mm 018384 The heater shall be secured to the wall using the 2 keyholes located in the spacer rear by the supplied screws Fit the two screws into the wall and leave approximately 2mm gap see...

Страница 6: ...the mantel switches located at the right side wall of mantel or by the supplied remote control Manual Operation NOTE The heater only starts working if the set temperature is higher than the ambient room temperature Heater powered off Heater powered on set to standby mode Press to switch the flame effect ON OFF Press and hold to toggle between 5 different flame dim levels Press to activate low leve...

Страница 7: ...he ON OFF switch before it can be operated using the mantle switches Heater powered off Heater powered on set to standby mode Press to switch the flame effect ON OFF Press and hold to toggle between 5 different flame dim levels Press to activate low level heating 1000W Press to activate high level heating 2000W ...

Страница 8: ...res 2xAAA size batteries Open the battery compartment by sliding the cover down and insert the batteries noting the polarity indicated in the battery compartment Keep batteries out of reach of children Remote control operations are identical to the functions on the control panel The remote control must be point directly at the sensor on control pad ...

Страница 9: ...s the or key to set the temperature which ranges from 15 to 30 After the temperature setting has been completed the display flashes about 5 seconds then shows the room temperature Setting timer Up to 10 different timer settings can be programmed Each timer setting has its day power on time and power off time The maximum duration of each timer setting is 23 hours 50 minutes If the power off time of...

Страница 10: ... effect goes on at the set power on time Automatic heating mode Press the IC key to activate automatic heating mode The AUTO icon appears on the display When the automatic heating is turned on the heater automatically changes the heating level depending on the set temperature and the ambient room temperature Maintenance WARNING Before any maintenance and or cleaning the exterior of the heater disc...

Страница 11: ... Not applicable At nominal heat output elmax 0 014 KW Type of heat output room temperature control select one At minimum heat output elmin 0 014 KW single stage heat output and no room temperature control no In standby mode elSB 0 48 W Two or more manual stages no room temperature control no with mechanic thermostat room temperature control no with electronic room temperature control no electronic...

Страница 12: ...he terminals in your plug as follows The BLUE wire is the NEUTRAL and must be connected to the terminal which is marked with the letter N or coloured BLACK The BROWN wire is the LIVE and must be connected to the terminal that is marked with the letter L or coloured RED The wire which is coloured GREEN YELLOW must be connected to the terminal which is marked E or the earth symbol or coloured GREEN ...

Страница 13: ... caused by mis use of the Product or where normal standards of care and use have not been complied with c Damage through a malfunction or an inadequately installed electric fire d Damage or defects due to mis use accident or unauthorised alterations 4 During the twelve months after the Product has been supplied the Guarantee covers the make good whether by repair or replacement at the Company s op...

Страница 14: ...ompatibility 2014 30 EU and the RED standards EN300220 2 EN301489 1 EN301489 3 and EN6247 which covers the essential requirements of the European Radio Equipment Directive 2014 53 EU This fire complies with the Safety Standards BS 60335 1 and BS 60335 2 30 which covers the essential requirements of the Electrical Equipment Safety Regulations 2016 and the EMC standards BS 55014 1 BS 55014 2 BS 6100...

Страница 15: ...Serviceable Replacement Parts 13 Fuel Bed 63 Remote Control ...

Отзывы: