BELTTT BEP300SA Скачать руководство пользователя страница 1

Product detail parameters

The using manual of the

pure sine wave inverter

Power Inverter
Solar Power Generation System

WARNING

Prohibit parallel connected with municipal electricity 

The inverter would be damaged when the output parallel connected with municipal
electricity,Leading to the danger of touching the electric.

Prohibit Minors use.

Don't use the inverter for minors. Because the output of inverter is high voltage, 
Leading to the danger happen for touching the electric

Prohibit uninstall

Don't uninstall and modify the inverter, leading to the fault of inverter if uninstall and
modify the inverter, and other accident include fire or touch electric etc.

Prohibit touch with club

Don't put club and other metal something  at near hole and socket of the inverter.
Leading to the fault of the touch electric and damage the inverter.

Prohibit touch with wet hand.

Don't touch the inverter and the plug with wet hand ,otherwise leading the touch
electric and other safety accident.

Keep away the flame and high temperature area

The inverter and battery will happen fire and exploded when the inverter work at
near the high temperature and flame area.

Prohibit knock

Knocking the inverter ,leading to the inverter damaged and other safety problem .

Prohibit use to the medical equipment.

The inverter don't use for the medical equipment ,Because of don't test and check
the equipment.

The character of product

The company's pure sine series inverter with perfect protection circuit, providing high

  temperature protection, over-voltage protection, low-voltage protection, short-circuit
  protection, overload protection and other functions to prevent damage to your inverter;

Advanced circuit design, high conversion efficiency, rich interface, stable output voltage;

The inverter adopts metal shell, reasonable design and good heat dissipation

  characteristic. 

The inverter has advanced anti-jamming technology, complete function protection

  circuit and soft start circuit, convenient operation mode. 

The soft-start circuit has the ability to raise the output voltage step by step during

  startup to eliminate the cold start failure, and at the same time, it has the output
  voltage instantaneous. Drop-down and fast recovery function to reduce the load on
  the instant overload.

Please connect to the ground wire

In order to using electric safety,Please connect to the ground wire otherwise
leading to the safety accident.

Prevent wet and water

Notice the preventing wet and water,Because of the wet and water,the inverter may
be damaged ,Leading to the fire and short circuit ,touch electric accident etc.

Please insert fully.

Please insert fully the load equipment's plug to the inverter power socket. if
the plug isn't inserted fully .Leading to the touch electric and over heat ,even
leading to the fire. Prohibit use the bad plug,socket, and electric wire.

    In order to ensure reliable service for you ,the inverter
must  be  installed  and  used  by  the  correct  way.  Please
reading  the  installing  and  operation  manual  before
installing  and  using.  please  especially  notice  the Alarm
and illustrate alarm. To some possible inverter damaged
that these used condition and used way is reminded. To
some possible damage to people ,which give any serious
alarm  notice.  Please  carefully  read  the  manual  of  the
product,  which  in  order  to  correct  use  .Especially  read
the  notice  of  safety  precautions,  and  safety  used. 

The security attention considered.

(must be read and remember)

  To avoid the injure to you and other person.we give
to as fellows notices,Please be sure compliance.The
means  all  kinds  of  symbols,Please  refer  to  the
instruction.  Warning:  please  read  carefully,the  as
follow content may harm person

Easy flammable gas 

Ensure no flammable gas before connect,The sparking will be brought when connect
the battery. 
The battery can bring the flammable gas when the battery is charged and discharged.
so the good vent should be keep.Don't put at some place of  bringing flammable gas.

                                                           

This series of 

Pure

 sine wave inverter is suitable for:

    Various kinds of household appliances, lighting electricity, IT electronics products, office
equipment, Power tools, on-board appliances, outdoor emergency power supply, etc. The
power of the electrical equipment exceeds the output power of the inverter and some
start-up current of large power equipment may not be driven.

300W

500W

800W

1000W

600W

1000W

110V / 220V

(

selectable

)

110V / 220V

(

selectable

)

1600W

2000W

12V

/

24V

/

48V

(

selectable

)

24V

/

48V

(

selectable

)

12V

 / 

24V

(

selectable

)

10

-

15V

(

12V

) / 

20

-

30V

(

24V

) / 

40

-

60V

(

48V

)

0.9A

(

12V

0.5A

(

24V

)

1.0A

(

12V

0.6A

(

24V

)

0.8A

(

12V

0.6A

(

24V

)

1.5A

(

12V

0.8A

(

24V

)

0.4A

(

48V

)

211

.

5

*

118

*

56

236

*

118

*

56

309

*

180

*

142

367

*

150

*

76

0.81

0.91

3.05

2.44

90

%

10V±0.5V

(

12

V

) / 

20V±1V

(

24V

) / 

40

V±2V

(

48V

)

10

.5V±0.5V

(

12

V

) / 

21V±1V

(

24V

) / 

42

V±2V

(

48V

)

15

.5V±0.5V

(

12

V

) / 

30V±1V

(

24V

) / 

60

V±2V

(

48V

)

BEP800S

1500W

2000W

3000W

5000W

3000W

4000W

6000W

10000W

12V

 / 

24V / 48V

(

selectable

)

10

-

15V

(

12V

) / 

20

-

30V

(

24V

) / 

40

-

60V

(

48V

)

384

*

180

*

142 454

*

180

*

142

529

*

180

*

142

685

*

180

*

167

4

4.9

6.02

8

90

%

10V±0.5V

(

12

V

) / 

20V±1V

(

24V

) / 

40

V±2V

(

48V

)

10

.5V±0.5V

(

12

V

) / 

21V±1V

(

24V

) / 

42

V±2V

(

48V

)

15

.5V±0.5V

(

12

V

) / 

30V±1V

(

24V

) / 

60

V±2V

(

48V

)

BEP1500S

BEP2000S

BEP3000S

BEP5000S

3

.

8A

(

12V

2

.

0A

(

24V

)

1

.

2A

(

48V

)

2

.

5A

(

24V

)

1

.

4A

(

48V

)

1.8A

(

12V

1.0A

(

24V

)

0

.

5A

(

48V

)

3.0A

(

12V

1

.

5A

(

24V

)

0

.

8A

(

48V

)

50Hz

 / 

60Hz

(

selectable

)

50Hz

 / 

60Hz

(

selectable

)

P

ure

 

Sine

 

Wave

P

ure

 

Sine

 

Wave

High temperature protection

Shortcircuit Protection

Overload Protection

High temperature protection

Shortcircuit Protection

Overload Protection

Intelligent fan, high temperature, load self start

Intelligent fan, high temperature, load self start

Support

No-support

No-support

No-support

Support

Support

Support

USB

Weight

(

kg

)

Rated Power

Peak Power

Output voltage

Frequency

Output

Input

Input

protected

of

battery

WaveForm

Battery

Voltage

Rang Voltage

Alarm voltage of

low voltage

Protected voltage of

battery low voltage

Protected voltage of

battery high  voltage

Anti-connected

protect battery

Other protect

F

AN

Working environment

Dimension

(

mm

)

Efficiency

Open Circuit

Losses

T Y P E

USB

Weight

(

kg

)

Rated Power

Peak Power

Output voltage

Frequency

Output

Input

Input

protected

of

battery

WaveForm

Battery

Voltage

Rang Voltage

Alarm voltage of

low voltage

Protected voltage of

battery low voltage

Protected voltage of

battery high  voltage

Anti-connected

protect battery

Other protect

F

AN

Working environment

Dimension

(

mm

)

Efficiency

Open Circuit

Losses

T Y P E

Working temperature 0-40 

 @ 100% load, working humidity 20-90 RH, no refrigeration

Working temperature 0-40 

 @ 100% load, working humidity 20-90 RH, no refrigeration

Отзывы: