background image

Product detail parameters

                                                           

This series of 

Small

 

Power

 inverter is suitable for:

    Various kinds of household appliances, lighting electricity, IT electronics products, office
equipment, on-board appliances, outdoor emergency power supply, etc. The power of the
inductive load and the electrical equipment exceeds the output power of the inverter and
some start-up current of large power equipment may not be driven.

Small Power

Inverter

 

Manual

 

    To ensure reliable service, the inverter must be used properly. 

Please  read  the  instruction  manual  before  use.  Particular

attention  should  be  paid  to  the  warning  and  attention  of  this

brochure. Caution for certain conditions and practices that may

cause  damage  to  the  inverter.  Make  clear  warning  statements

about  certain  conditions  and  practices  that  may  cause  bodily

harm. Please read all instructions before using the inverter.      

    Please read this instruction manual carefully so that it can be

used  correctly.  Remember  to  read  the  "safety  precautions" 

section  before  you  use  it  to  make  sure  it's  safe  to  use.  After

reading the instructions, please complete the warranty card for

safekeeping, to keep on for reference.                                          

Power Inverter
Solar Power Generation System

To  avoid  harm  to  you  and  others,  here  are

some of the following security considerations. 

Be sure to follow the meanings of the various

flags. See the following.

WARNING

Inammable gas

When connected to a battery, sparks are produced. Make sure there is no ammable

gas before connecting.

The battery will produce ammable gas when charging and discharging. It should be

well ventilated and should not be stored in other places where it is ammable

No parallel with city power

The output can not be paralleled with the power supply, it will damage the inverter and
cause the danger of electric shock

Minors are prohibited from using them

Can not be used by minors, inverter output is high voltage, may lead to electric shock
risk

No disassembly or assembly

Do not disassemble or modify the inverter without permission. Unauthorized removal
or modication of the inverter may result in a safety accident such as a malfunction, 
re or electric shock

Bar contacts are prohibited

Do not place bars or other metal objects at the opening or socket of the inverter. This
may touch the internal parts and cause electric shock and inverter damage

Keep away from re and high temperatures

Fire and explosion can occur in inverter and battery when running in ame and high
temperature region

Wet hands, do not touch

Do not touch the body and plug with wet hands, which may cause electric shock and
personal safety

No throwing

Bumping the inverter can cause damage and other safety hazards.

Medical equipment disabled

This inverter has not been tested and can not be used in medical equipment

Moisture proof and waterproof

Please pay attention to moisture proof and waterproof. The inverter
may cause short circuit, re and electric shock due to humidity or water
inow

Please insert completely

Please insert the load device plug into the inverter socket completely. If
the plug is fully inserted at the end, it may lead to electric shock and
overheating, and even cause a re accident. Do not use damaged plugs, 
power outlets, electrical wires

Product characteristics

Our company's pure sine wave series inverter has perfect protection circuit, provide high

   temperature protection, overpressure protection, low voltage protection, short circuit
   protection, overload protection and other functions to prevent damage to your inverter;

Advanced circuit design, high conversion efficiency, rich interface, stable output voltage;

The inverter is made of metal shell, which has reasonable design and good heat dissipation

   performance;

The inverter has advanced anti-jamming technology, fully functional protection circuit, soft

   start circuit and convenient operation mode.

The soft start circuit increases the output voltage step by step at startup in order to eliminate

   cold start failure, and also has the instantaneous drop of the output voltage and the quick
   recovery function, which reduces load on startup instantly overload.

Please connect the ground wire.

In order to ensure the safety of use, please connect the ground wire.

BEL150XTU

 / 

BEL200XTU

BEL300ST

 

/

 

BEL300H / BEL350ST 

BEL500ST

 

/

 

BEL500H / BEL550ST 

50Hz

 / 

60Hz

(

Optional

)

50Hz

 / 

60Hz

(

Optional

)

Modified

 

Sine

 

Wave

Modified

 

Sine

 

Wave

High temperature protection

Shortcircuit Protection

Overload Protection

High temperature protection

Shortcircuit Protection

Overload Protection

Smart fan,

Automatic startup of high temperature and load

Smart fan,

Automatic startup of high temperature and load

Temperature 0

℃~

40

℃@

100%load, Humidity 20%~90%RH,No refrigeration

Temperature 0

℃~

40

℃@

100%load, Humidity 20%~90%RH,No refrigeration

Remarks

Please select the corresponding parameters according to the 

BEL150XTU BEL200XTU BEL300ST

BEL300H

BEL500ST

BEL800ST

BEL1000ST

BEL350ST

BEL550ST

150W

300W

12V

/

24V/48V

60V

(

Optional

)

12V

/

24V/48V

60V

(

Optional

)

12V

/

24V/48V

60V

(

Optional

)

12V

/

24V/48V

60V

(

Optional

)

12V

/

24V/48V/60V

72V

(

Optional

)

12V

/

24V

(

Optional

)

12V

/

24V

(

Optional

)

12V

/

24V/48V

(

Optional

)

12V

 / 

24V

(

O

ptional

)

10

-

15V

(

12V

)/

20

-

30V

(

24V

)/

40

-

60V

(

48V

)/

50

-

70V

(

60V

)/

60

-

90V

(

72V

)

0

.

5A

(

12V

0

.

3A

(

24V

)

0

.

5A

(

12V

0

.

3A

(

24V

)

0

.

3A

(

12V

0

.

2A

(

24V

)

0

.

3A

(

12V

0

.

2A

(

24V

)

0

.

15A

(

48V

)

0

.

1A

(

60V

)

0

.

5A

(

12V

0

.

4A

(

24V

)

0

.

2A

(

48V

)

0

.

15A

(

60V/72V

)

N

o

N

o

91*63*37.5 106*63*37.5 152*95*55

193*95*55

162*95*55

248

350

438

466

566

48V/60V

(

Yes

)

48V/60V

/

7V

(

Yes

)

Y

es

O

ptional

O

ptional

300W

600W

300W

600W

500W

300W

1000W

600W

85

%

12

V

(

9

.5V±0.5V

)/

24V

(

19V±1V

)/

48V

(

40

V±2V

)

/60V(50V±3V)/72V(60V±3V)

12

V

(

15.5V±0.5V

)/

24V

(

30V±1V

)/

48V

(

60V±2V

)

/60V(74V±3V)/72V(90V±3V)

12

V

(

No

)/

24V

(

No)

/

48V

(

4

2V±2V

)/

60V

(

53V±3V

)/

72V

(

63V±3V

)

12

V

(

No

)/

24V

(

No

)/

48V

(

4

2V±2V

)/

60V

(

53V±3V

)/

72V

(

63V±3V

)

0

.

3A

(

12V

0

.

2A

(

24V

)

0

.

15A

(

48V

)

0

.

1A

(

60V

)

152*95*55 193*95*55

438

566

BEL5000H

800W

1600W

10

-

15V

(

12V

)/

20

-

30V

(

24V

)/

40

-

60V

(

48V

)/

50

-

70V

(

60V

)/

60

-

90V

(

72V

)

1A

(

12V

0

.

6A

(

24V

)

0

.

25A

(

48V

)

0

.

5A

(

12V

0

.

4A

(

24V

)

1A

(

12V

0

.

7A

(

24V

)

0

.

2A

(

48V

)

0

.

15A

(

60V

)

0

.

5A

(

12V

0

.

4A

(

24V

)

0

.

2A

(

48V

)

0

.

15A

(

60V/72V

)

Y

es

226*95*55

193*95*55

241*95*55

790

620

855

48V/60V

(

yes

)

48V/60V

(

yes

)

48V/60V

/

72

v

(

yes

)

Y

es

1000W

2000W

500W

1000W

550W

350W

1100W

700W

85

%

12

V

(

9

.5V±0.5V

)/

24V

(

19V±1V

)/

48V

(

40

V±2V

)

/60V(50V±3V)/72V(60V±3V)

12

V

(

15.5V±0.5V

)/

24V

(

30V±1V

)/

48V

(

60V±2V

)

/60V(74V±3V)/72V(90V±3V)

Rated Power

Peak Power

Frequency

Output

Input

Battery

input

protection

WaveForm

Battery

Voltage

Voltage

Range

Low Voltage Alarm

Battery low

voltage protection

Battery high

voltage protection

Battery reverse

polarity protection

Other protection

USB

F

AN

Operating

environment

S

ize

(

mm

)

W

eight

(

g

)

Efficiency

No load

Current

M O D E L

Rated Power

Peak Power

Frequency

Output

Input

Battery

input

protection

WaveForm

Battery

Voltage

Voltage

Range

Low Voltage Alarm

Battery low

voltage protection

Battery high

voltage protection

Battery reverse

polarity protection

Other protection

USB

F

AN

Operating

environment

S

ize

(

mm

)

W

eight

(

g

)

Efficiency

No load

Current

M O D E L

Отзывы: