background image

View Bell Medium 3 CF 
Direct Vent Gas Fireplace

Operating manual

 

-  Do not store or use gasoline or other fl ammable vapors and liquids in   

 

 

the vicinity of this or any other appliance.

 

-   WHAT TO DO IF YOU SMELL GAS:

 

 

•   Do not try to light any appliance.

 

 

•   Do not touch any electrical switch; do not use any phone in your    

 

 

    building.

 

 

•   Immediately call your gas supplier from a neighbor’s phone.  

 

 

    Follow the gas supplier’s instructions.

 

 

•   If you cannot reach your gas supplier, call the fi re department.

 

-  Installation and service must be performed by a qualifi ed installer, 

 

 

service agency or the gas supplier.

 

WARNING:

 If the information in these instructions are not 

 

followed exactly, a fi re or explosion may result causing property damage,  

 

personal injury or loss of life.

 

This appliance may be installed in an aftermarket, permanently located,   

 

manufactured home (USA only) or mobile home, where not prohibited by 

 

local codes. This appliance is only for use with the types of gas indicated 

 

on the rating plate. A conversion kit is supplied with the appliance.

WARNINGS

HOT GLASS 

WILL 

CAUSE BURNS.

 

DO NOT TOUCH 

GLASS

UNTIL COOLED.

NEVER 

ALLOW CHILDREN

TO TOUCH GLASS.

WARNING

  INSTALLER: Leave this manual with  
  the appliance.

  CONSUMER: Retain this manual for 
  future reference.

Содержание VIEW BELL TOPSHAM 3 CF

Страница 1: ...rmed by a quali ed installer service agency or the gas supplier WARNING If the information in these instructions are not followed exactly a re or explosion may result causing property damage personal...

Страница 2: ......

Страница 3: ...INSTRUCTIONS 5 CODE APPROVAL 7 OPERATING INSTRUCTIONS 8 INTRODUCTION 8 SAFETY 8 FLAME EFFECT 11 REMOTE CONTROL 13 USING THE APPLIANCE FOR THE FIRST TIME 27 CLEANING AND MAINTENANCE 28 DAILY MAINTENANC...

Страница 4: ...4 Bell res Instructions for use...

Страница 5: ...Toddlers young children and others may be susceptible to accidental contact burns The remote control handset should be kept out of reach of children A physical barrier is recommended if there are at r...

Страница 6: ...needed have the venting system cleaned or repaired 17 When the appliance is installed directly on carpeting tile or other combustible material non combustible it must be set on a metal panel or hearth...

Страница 7: ...EPLACES View Bell Medium 3 CF tested to ANSI Z21 88 2009 CSA 2 33 2009 Vented Gas Fireplace Heaters ANSI Z21 88a 2012 CSA 2 33a 2012 Addenda 1 to ANSI Z21 88 2009 CSA 2 33 2009 CSA P4 1 09 Testing met...

Страница 8: ...ll relieve in a controlled manner a potential developing overpressure Thus by means of a spring system the door will tilt a few inches forward This may cause a loud noise If this happens immediately c...

Страница 9: ...ic ue system and the outlet are cleaned and inspected annually by a recognised tter gas specialist The safe operation of the appliance will thus remain guaranteed For this please refer to the Installa...

Страница 10: ...service technician to inspect the appliance and replace any part of the control system and any gas control which has been submerged in water Use only the remote control to operate the appliance Never...

Страница 11: ...ials such as nylon clothing or combustible liquids in the vicinity of the appliance Ensure at all times that children and other people who are not aware of the operation of the gas appliance are only...

Страница 12: ...ame effect is dependant on the composition and supply pressure of the natural gas present Propane The ame effect produced by propane is less realistic than with natural gas The ame effect is less as f...

Страница 13: ...to open this will release the catch and the door will spring out The hand held transmitter and receiver are powered by batteries Hand held transmitter 1x 9V battery Receiver 4x 1 5V battery type LR6 o...

Страница 14: ...ode Figure 2 Display hand held transmitter ON OFF Temperature setting Possibilities of operation Company modes Program Timer setting Temperature setting Fan symbol has no function for the appliance Si...

Страница 15: ...e minute Wait or press OFF to return to mode Important Setting up signal code before using the appliance for the rst time Before the appliance can be used the receiver must rst learn the hand held tra...

Страница 16: ...urner consists of a front burner and a rear burner Burner operation described below applies to 1 Both front burner and rear burner The AUX symbol on the hand held transmitter s display is visible or 2...

Страница 17: ...as no function for the appliance 4 Has no function for the appliance 5 Operating night temperature thermostat 6 Timer setting You can cycle through the menu with operating possibilities by repeatedly...

Страница 18: ...o turn the burner off The pilot light will keep burning Stand by position The appliance will automatically revert to stand by if the batteries in the receiver are fully depleted The pilot light will a...

Страница 19: ...e the temperature at night the night temperature must be set to at least 5 C If the setting is lowered to the appliance will switch to stand by at night The appliance will automatically operate at the...

Страница 20: ...on the display The AUX symbol on the hand held transmitter s display indicates that the front burner and rear burner are both being operated All functions apply to both burners together If the AUX sym...

Страница 21: ...y close the gas tap and warn the tter If the main burner ignites with a pop immediately close the gas tap and warn the tter Motor knob Microswitch 8 wire Receiver Jack Pilot gas adjustment screw Facto...

Страница 22: ...nd to turn off the burner Extinguishing the re small ame button pilot light remains burning standby position Pressing brie y the small ame button gradually lowers the ames to the low position Pressing...

Страница 23: ...ition Pressing the large ame button twice automatically increases the ames to the high position This is indicated by HI on the display Important If you turn on the burner by pressing the large ame but...

Страница 24: ...uctions for turning the rear burner on and off After igniting the pilot light and burner the front burner and rear burner are both ON The AUX symbol on the hand held transmitter s display is visible T...

Страница 25: ...is reduced to 3 If the receiver s batteries are depleted the rear burner remains in the last chosen setting IN or OUT During normal use the rear burner will be automatically turned ON if the appliance...

Страница 26: ...s this in the display Battery fully charged Battery empty 2 Receiver 3x short audio signal audible when the motor knob operates 1 Hand held transmitter Open the cover on the back of the transmitter Ca...

Страница 27: ...esult in an unpleasant smell This is harmless however Operating the appliance at full capacity for a few hours while ventilating the room will eliminate the smell After using your appliance for the rs...

Страница 28: ...ervice technician perform these check ups at the beginning of the heating season WARNING If the glass is not cleaned on time this can result in becoming dull and dif cult if not impossible to clean Ca...

Страница 29: ...ler for replacement If anything is spilt on the re switch it off immediately and wait for it to cool down suf ciently before cleaning Never use scouring powder aggressive cleaners or re polish on the...

Страница 30: ...OL COMPARTMENT Keep the control compartment and burner areas surrounding the wood logs pebbles or glass clean by brushing or vacuuming at least once a year Make sure the burner porting pilot air openi...

Страница 31: ...is dependent on the type of installation vent system con guration Also wind may have an effect on the ame appearance VENT Check the venting system at least once a year to ensure that nothing is blocki...

Страница 32: ...itions 2 1 Should you wish to claim under the warranty please contact your Bell res dealer 2 2 Complaints should be reported as quickly as possible after they have manifested themselves 2 3 Complaints...

Страница 33: ...erior of the combustion chamber a similar guarantee is given until after the rst burning Article 6 Liability 6 1 A claim granted by Interfocos B V under this warranty does not automatically imply that...

Страница 34: ...34 Bell res Instructions for use...