Bellfires Smart Bell 75- 55 MF Скачать руководство пользователя страница 1

Preparation manual

Smart Bell 75/55 MF

Serial number:

Production date:

Содержание Smart Bell 75- 55 MF

Страница 1: ...Preparation manual Smart Bell 75 55 MF Serial number Production date...

Страница 2: ...without the prior written permission of Barbas Bellfires BV This document could contain technical inaccuracies or typographical errors Barbas Bellfires BV reserves the right to revise this document fr...

Страница 3: ...ical specification 17 5 1 Dimensions Smart Bell 75 55 with a Built in frame 17 5 2 Dimensions Smart Bell 75 55 with a Classic frame 35 mm 18 5 3 Dimensions Smart Bell 75 55 with a Classic frame 52 mm...

Страница 4: ...typical setup The illustrations are for instructional use only 1 1 How to work with this document 1 Make yourself familiar with the structure and content of the document 2 Read the safety chapter in d...

Страница 5: ...e The in ner pipe is used as flue gas channel and the space be tween the inner pipe and the outer pipe is used as combustion air channel Flue gas channel The flue gases from the appliance flow through...

Страница 6: ...pecified in this manual and the related documents Only use the following brands for the installation of the concentric flue system Manufacturer system Bellfires Muelink Grol system Poujoulat DUOGAS sy...

Страница 7: ...r is made of flammable material take correct safety measures Install a temperature protection plate made of nonflammable material between the appliance and the floor The appliance must be installed in...

Страница 8: ...ectives for the exact minimum distances If the outlet is installed horizontally in less than 0 5 m and vertically in less than 2 m from a public area install an effective protector Make sure that the...

Страница 9: ...e sure that the casing is made of heat resistant material Make sure that air can flow in the casing Use grates near the floor and near the ceiling Do this for every floor where the casing is located D...

Страница 10: ...a roof outlet Rigid concentric flue systems 4 28 100 1 10 11 12 13 23 24 17 16 24 18 16 Y Y min max Flue gas restriction plate width Concentric connection on the appliance is 100 150 mm 2 0 4 0 m 30...

Страница 11: ...Y2 Y1 min max X min max Y1 Y2 min max Flue gas restriction plate width Concentric connection on the appliance is 100 150 mm 1 0 11 0 m 0 3 0 m 1 0 11 0 m Caution Make sure that Y1 Y2 is at least 2 tim...

Страница 12: ...29 23 25 18 10 11 12 13 Y Y min max Flue gas restriction plate width Concentric connection on the appliance is 100 150 mm 2 0 4 0 m 30 mm 4 0 12 0 m 40 mm Roof outlet using an flexible 100 mm liner in...

Страница 13: ...min max Flue gas restriction plate width Concentric connection on the appliance is 100 150 mm 1 0 11 0 m 0 3 0 m 1 0 11 0 m Caution Make sure that Y1 Y2 Y3 is at least 2 times larger than X Roof outle...

Страница 14: ...x Flue gas restriction plate width Concentric connection on the appliance is 100 150 mm 2 0 4 0 m 30 mm 4 0 12 0 m 40 mm Roof outlet using an flexible 100 mm liner and flexible 150 mm liner in an exis...

Страница 15: ...ion Make sure that Y1 Y2 Y3 is at least 2 times larger than X Roof outlet using an flexible 100 mm liner and flexible 150 mm liner in an existing unsound lined chimney 4 4 2 Possibilities for a concen...

Страница 16: ...systems 19 1 10 11 12 13 4 28 100 14 Y 0 16 m X Y min max X min max Flue gas restriction plate width Concentric connection on the appliance is 100 150 mm 1 0 1 5 m 0 3 5 m 1 5 3 0 m 0 8 0 m Requiremen...

Страница 17: ...5 Technical specification 5 1 Dimensions Smart Bell 75 55 with a Built in frame Technical specification Smart Bell 75 55 17...

Страница 18: ...5 2 Dimensions Smart Bell 75 55 with a Classic frame 35 mm Technical specification 18 Smart Bell 75 55...

Страница 19: ...5 3 Dimensions Smart Bell 75 55 with a Classic frame 52 mm Technical specification Smart Bell 75 55 19...

Страница 20: ...5 4 Dimensions Smart Bell 75 55 with a Classic frame 70 mm Technical specification 20 Smart Bell 75 55...

Страница 21: ...5 5 Dimensions Smart Bell 75 55 with an Insert frame 15 mm Technical specification Smart Bell 75 55 21...

Страница 22: ...5 6 Dimensions Smart Bell 75 55 with an Insert frame 50 mm Technical specification 22 Smart Bell 75 55...

Страница 23: ...nsert frame 50 mm and Convection fan 5 8 Dimensions of the restriction plate Width of the delivered flue restriction plates in mm Concentric flue connection 100 150 Roof mounted outlet 30 40 50 65 Tec...

Страница 24: ...apter The guarantee on the appliance lapses if it is installed fully or partially with other components or a different flue system The concentric flue 100 mm 150 mm systems can be used with either a n...

Страница 25: ...Twin wall balanced flue pipe L 500 mm 11 302290 Twin wall balanced flue pipe L 1000 mm 12 302291 Telescopic twin wall balanced ue pipe L min 325 max 440 mm 13 302292 Adjustable length twin wall balanc...

Страница 26: ...h 20 45 with lead ashing 18 302213 Roof ashing for existing chimney or at roof 19 302296 Horizontal wall termination kit L 600 mm adjustable including a set of wall spacer plates 20 302293 Stainless s...

Страница 27: ...79 Stainless steel adapter piece 150 re to exible 148 mm external rigid x 148 mm internal ex appliance 150 mm ex 28 302217 Stainless steel locking band 150 mm For adapter 150 appliance 150 mm ex Screw...

Страница 28: ...entric bend with in spection panel 36 321948 Universal wall oor support 150 mm Color rvs Stainless steel self color polished antr Anthacite color lacquer matt Adjustable roof flashing for a slope 45 c...

Страница 29: ...anced flue pipe L 450 mm 11 37100405 Twin wall balanced flue pipe L 950 mm 12 37100429 Telescopic twin wall balanced ue pipe L min 390 max 640 mm 14 37100441 Twin wall balanced ue el bow 90 15 3710042...

Страница 30: ...roof pitch of 15 30 17 45150172 Roof ashing suitable for a brick roof with a roof pitch of 30 45 17 45150173 Roof ashing suitable for a tiled roof with a roof pitch of 30 45 18 45150169 Roof ashing f...

Страница 31: ...0428 Set of ceiling nishing plates Fire stops suitable for a roof pitch of 40 50 34 37100407 Concentric pipe with inspec tion opening L 250 mm 36 45150165 Roof support universal 150 mm 36 45150081 Flo...

Страница 32: ...all balanced ue pipe L 250 mm 10 US 50 10 Twin wall balanced flue pipe L 500 mm 11 US 100 10 Twin wall balanced flue pipe L 1000 mm 12 USPP 10 Telescopic twin wall balanced ue pipe L min 60 max 250 mm...

Страница 33: ...S 10 Adjustable roof ashing Roof pitch 20 45 with lead ashing 17 USDH 10 Roof ashing plate for roof pitch 5 30 18 USDP 10 Roof ashing for existing chimney or at roof 18 USDPAL 10 Roof ashing Aluminium...

Страница 34: ...USMB 10 Wall strap adjustable 23 USEB 10 Fitting bracket 24 USCP 10 Set of ceiling nishing plates Fire stops Centring plates 24 USDQ 10 Roof support 25 USSAN 10 Renovation set 25 USSAN1 10 Top of reno...

Страница 35: ...on panel L 250 mm 34 USEM 10 Concentric pipe with gauging ori ce L 150 mm 35 USBI 10 90 concentric bend with in spection panel USR 10 Rosette smooth 150 mm USMPG 10 Wall plate large 150 mm square 300...

Страница 36: ...0 mm 10 ATWINL 15 100 150 Twin wall balanced flue pipe L 250 mm 12 H TWIN 742 100 150 Telescopic twin wall balanced ue pipe L min 1100 max 1400 mm 12 H TWIN 467 100 150 Telescopic twin wall balanced u...

Страница 37: ...8 100 150 Twin wall balanced ue el bow 45 14 ATWIN 60 100 150 Twin wall balanced ue el bow 90 14 ATWIN 60F 100 150 Twin wall balanced ue el bow 90 Short Especially for connection to a wall termi natio...

Страница 38: ...f ashing for roof pitch 30 with lead ashing and storm collar 17 ATWIN 60DD 100 150 Roof ashing for roof pitch 45 with lead ashing and storm collar ATWIN 307 100 150 Storm collar 24 ADBL DW 100 150 Set...

Страница 39: ...Inspection panel with cover cap and condensation opening ATWIN 465 100 150 Adapter H TWIN 100 150 Flex Stainless steel 100 mm Incl Ceiling plate 300x300 mm ATWIN 466 100 150 Adapter Flex Stainless st...

Страница 40: ...ing locking band 2x 11 TWG13 100 150 Twin wall balanced ue pipe L 1000 mm Including lock ing band 10 TWG14 100 150 Twin wall balanced ue pipe L 500 mm Including locking band 10 TWG15 100 150 Twin wall...

Страница 41: ...Including locking band 15 TWG18 100 150 Twin wall balanced ue el bow 45 Including locking band 14 TWG60 100 150 Twin wall balanced ue el bow 90 Including locking band 14 TWG1786 100 150 Twin wall bala...

Страница 42: ...lu ashing and storm collar 17 TW38 150 Roof ashing with a roof pitch of 26 35 With ex alu ashing and storm collar 17 TW54 150 Roof ashing with a roof pitch of 36 45 With ex alu ashing and storm collar...

Страница 43: ...mm ZU WA891200 Extension pieces for the wall strap ZUWA704 L 200 mm ZU WA891250 Extension pieces for the wall strap ZUWA704 L 250 mm ZUWA706 Extension pieces for the wall strap ZUWA704 L 400 mm WA 50...

Страница 44: ...ceiling plate with adapter FLEX to TWIN GAS 25 ZUWA1618 100 Adapter TWIN GAS to Schaft DE 25 TWG1732 100 150 Chimney at roof ceiling plate with adapter 100 rig id ex to TWIN GAS 33 TWG317 100 150 Conc...

Страница 45: ...with transverse support Type II 500 mm Distance to wall WA 50 150 mm DW393 Wall support with transverse support Type III 750 mm Distance to wall WA 150 250 mm DW407 Wall support with transverse suppor...

Страница 46: ...Available components for the concentric flue system 46 Smart Bell 75 55...

Страница 47: ...Available components for the concentric flue system Smart Bell 75 55 47...