background image

U

User manual

Room Divider Medium 3 CF/LF/MF

Room Divider Medium 3 L/R CF/LF/MF

Serial number:

Production date:

Содержание ROOM DIVIDER MEDIUM 3 CF

Страница 1: ...U User manual Room Divider Medium 3 CF LF MF Room Divider Medium 3 L R CF LF MF Serial number Production date...

Страница 2: ...hout the prior written permission of Barbas Bellfires BV This document could contain technical inaccuracies or typographical errors Barbas Bellfires BV reserves the right to revise this document from...

Страница 3: ...1 3 Safety 12 3 1 Safety devices on the appliance 12 3 2 Safety instructions for operation 12 3 3 Safety instructions with regard to the environment 13 4 Operation 14 4 1 Preparation before first use...

Страница 4: ...glass 23 6 Troubleshooting 24 6 1 Troubleshooting table 24 6 2 Troubleshooting procedures 24 6 2 1 Replace the batteries of the remote control 24 7 Technical data 26 7 1 Room Divider Medium 3 L R CF...

Страница 5: ...The illustrations are for instructional use only 1 1 How to work with this document 1 Make yourself familiar with the structure and content of the document 2 Read the safety chapter in detail 3 Make s...

Страница 6: ...e and right side not visible in the picture of the ap pliance E Front panels 2 decorative steel panels surrounding the un derside of the glass panels F Extended adjustable feet 4 adjustable feet at th...

Страница 7: ...stable feet only for built in installation 2 3 Overview of the remote control Note The remote control is not interchangeable with a remote control from a different model You can operate the appliance...

Страница 8: ...is set D Program number To show that program 1 or 2 is active E Temperature To show the set temperature F AUX function To show that both burners are on G Eco mode To show that the eco mode is set H T...

Страница 9: ...ature on specific times and days 2 4 3 Eco mode In this mode the flame height changes between minimum and maximum height for the duration of a cycle If the room temperature is lower than the set tempe...

Страница 10: ...tage current OUT yellow connection Connection to the thermoelectric pilot light shut off wire OUT G Piezo cable connection Connection for the piezo cable which is con nected to the ignition electrode...

Страница 11: ...ers the ambient light bulbs B Auxiliary connection Not used C connection for the power supply Connection for the 230 VAC power cable with an earthed plug Connection is also used for earthing the appli...

Страница 12: ...iance is installed correctly Refer to the Installation and Maintenance manual You can find the manuals on http bellfires com Make sure that the appliance is installed and connected as a room sealed sy...

Страница 13: ...ispose of batteries as chemical waste Dispose of ceramic heat resistant glass as household waste Do not dispose of ceramic heat resistant glass in a glass recycling container Dispose of an obsolete ap...

Страница 14: ...me height to maximum for 10 minutes to make sure the chimney becomes warm 4 Use the appliance with maximum flame height for several hours to remove the smell of the coating 5 When the appliance is coo...

Страница 15: ...hanges into 2 when the remote control is set to the two button operation The 2 changes into 1 when the remote control is set to the one button operation 4 2 2 Set the temperature scale If you set the...

Страница 16: ...nce with two button opera tion The remote control is set to the two button operation Refer to section 4 2 1 Push and at the same time Start the appliance from stand by mode The appliance is set to sta...

Страница 17: ...e Push Start the eco mode Push Stop the eco mode Push Start the countdown timer mode Push Stop the countdown timer mode Push Table 3 Start and stop the rear burner Note When you start the appliance th...

Страница 18: ...ht Increase the flame height Push and hold until you have the de sired flame height Set the flame height to maximum The background light ing is on Tap twice Set the flame height to minimum The backgro...

Страница 19: ...ximum thermostat 60 C The receiver in the appliance is fitted with a 60 C maximum thermostat When this thermostat is activated the main burner will be completely switched off and the pilot light will...

Страница 20: ...ld the program mode button until the program mode flashes and ON and the set temperature appears 2 Tap the program mode button to continue The display of the remote control shows OFF and the temperatu...

Страница 21: ...1 Push and hold the countdown timer button until the display shows the countdown timer symbol and the hour flashes 2 Use the up and down buttons to select the number of hour 3 Push the countdown timer...

Страница 22: ...efore the glass is replaced For disposal of the glass refer to 3 3 4 Clean the glass a If the inner side is dirty remove the glass Refer to the Installation and maintenance manual b Clean the glass re...

Страница 23: ...gloves to prevent fingerprints on the glass 2 Clean the glass with a soft cloth a sponge or tissue paper Use glas cleaner or ceramic hob cleaner 3 Make sure the glass is dry Water droplets can leave a...

Страница 24: ...ace the batteries of the re mote control Refer to section 6 2 1 The appliance does not re spond to the remote control The batteries of the remote control are empty The system has a failure On the rece...

Страница 25: ...e the cover of the remote control 2 Remove all batteries 3 Install new batteries For approved batteries refer to section 7 4 Close the cover of the remote control 1 2 Troubleshooting Room divider Medi...

Страница 26: ...8 1kW Nominal heat output 8 1 kW Butane G30 7 5 kW Propane G31 6 2 kW Minimum heat output indica tive 2 3 kW Butane G30 1 7 kW Propane G31 1 5 kW Useful efficiency Net Calorific Value NCV at nominal...

Страница 27: ...vider Medium 3 LF Room Divider Medium 3 L R LF Country GB IE ES IT GB IE ES IT Product identification no 0063CM3684 0063CM3684 Indirect heating functionality No No Type of appliance under CE norm C11...

Страница 28: ...aximum Appliance is on temperature Both burners at maximum Appliance is cold Both burners at minimum Heat changing surface Entire front of the appliance 7 3 Room Divider Medium 3 L R MF MagniFire Natu...

Страница 29: ...lectrical connection 230 VAC 50 Hz 230 VAC 50 Hz Auxiliary electricity consump tion at nominal heat output 0 075 kW 0 075 kW Auxiliary electricity consump tion at minimum heat output 0 kW 0 kW Auxilia...

Страница 30: ...after they have manifested themselves 3 Complaints will only be accepted if they are reported to the Bellfires dealer together with the serial number of the Bellfires appliance which is stated on the...

Страница 31: ...anty does not automatically imply that Barbas Bellfires B V also accepts liability for any possible damage The liability of Barbas Bellfires B V never extends further than that stated in these warrant...

Страница 32: ...9 9 EU Declaration of Conformity EU Declaration of Conformity 32 Room divider Medium 3...

Страница 33: ...EU Declaration of Conformity Room divider Medium 3 3 33...

Страница 34: ...EU Declaration of Conformity 3 34 Room divider Medium 3...

Страница 35: ...EU Declaration of Conformity Room divider Medium 3 3 35...

Страница 36: ...Y Your Bellfires dealer 001 14 06 2019 348717...

Отзывы: