PAGE 5
OPERATIONS AND MAINTENANCE PROCEDURES
CONVEYOR TOASTER MODELS
JT2-B
TROUBLESHOOTING GUIDE
1)
UNIT WILL NOT HEAT, CONVEYOR BELT WILL NOT MOVE.
a.
Check to make sure the toaster is PLUGGED IN.
b.
Push the HIGH TEMPERATURE LIMIT reset button as described on Page 3.
c.
After pushing the reset button, clean the air intake area to prevent further
occurrences.
d.
Make sure that the Crumb Tray is in place.
Operating the toaster without the
Crumb Tray in place may cause overheating in and around the control
housing.
2)
UNIT WILL NOT HEAT, CONVEYOR MOVES FREELY.
a.
Push the HIGH TEMPERATURE LIMIT reset button as described on Page 3.
b.
After pushing the reset button, clean the air intake area to prevent further
occurrences.
c.
Make sure that the Crumb Tray is in place.
Operating the toaster without the
Crumb Tray in place may cause overheating in and around the control
housing.
3)
EITHER TOP OR BOTTOM HEATER TUBES DO NOT HEAT.
a.
Call the Belleco, Inc. service group at 1-877-854-8006 as one or more Heater
Tubes may need replacing.
4)
TESTING FOR AND CLEARING MECHANICAL BINDING
a.
Remove side and bottom panels.
b.
Remove the drive sprocket and chain from the drive motor shaft. (Tip – Loosen
the drive motor mounting screws and slide the motor to loosen the chain)
c.
Slowly rotate the conveyor belt by hand to see where the binding is taking place.
Once it is discovered, clear the jam and re-assemble the toaster.
d.
Test under power. If the conveyor belt will not operate, call the Belleco, Inc.
service group at 1-877-854-8006 as either the Drive Motor and/or Speed Control
may need replacing.
HEATER TUBE GUIDE
Model #
Voltage
Part#
Wattage
Qty.
JT2-B Top Tubes
208
403004
1400
2 (Metal)
JT2-B Bot. Tubes 208
403002
200
2 (Metal)
JT2-B Top Tubes
208
204220
700
4 (Quartz)
JT2-B Bot. Tubes 208
204011
200
2 (Quartz)
JT2-B Top Tubes
220
204226
700
4 (Quartz)
JT2-B Bot. Tubes 220
204019
200
2 (Quartz)
JT2-B Top Tubes
240
403003
1400
2 (Metal)
JT2-B Bot. Tubes 240
403005
200
2 (Metal)
JT2-B Top Tubes
240
204221
700
4 (Quartz)
JT2-B Bot. Tubes 240
204032
200
2 (Quartz)