Recommended cables. Installation of the Touch Line video panels
3.1
Recommended cables
2
4 wires x 0.5 mm
(type
H03VV-F4G 0.5
) for maximum
60 ml
or another type of equivalent cable;
2
4 wires x 0.75 mm
(type
H05VV-F4G 0.75
) for maximum
150 ml
or another type of equivalent cable;
Generally, any type of 4-wire cable with a 0.5 mm section is accepted.
Telephone cables
type
TCYY -
2x2x0.5-24 AWG
(max. 30 ml);
TCYY -3x2x0.5-24 AWG
(max. 50 ml);
TCYY - 4x2x0.5-24 AWG
(max. 50 ml)
can also be used.
Note
: If the cable has more than 4 wires, the additional wires will be connected the same as in the case of
a
UTP cable
. The
+14
and
GND
connections are equally supplemented with the additional wires.
4 WIRE
Installation (standard)
+
14
C/D
6mm
20-25mm
GND
Vin
+
14
C/D
6mm 20-25mm
GND
V
out
SCU
Panel
2.2
Use
Orientable video camera
RFID reader
Microphone
Fastening Torx screw
LEDs (day and night white lighting)
Touch key with the name
of the family
Speaker
Fastening Torx screw
1 Fam.
5 Fam.
2 Fam., 3 Fam.
Fam 2
Fam 1
Fam 3
Fam 4
Fam 5
Fam 1
Presence sensors
LEDs signaling status during use
1. STAND-BY.
The keys with the names of the residents are off. The red LED blinks and signals the possibility of
video monitoring.
Note
: The Red LED can be disabled through jumper JP1 (RED LED) on the board of the keyboard, when the name
labels are added.
2. CALL + TALK + ACCESS
. The keyboard turns on when a person approaches the panel less than 1m away. Touch
the key corresponding to the name of the family you are looking for. The panel signals the call acoustically, with a beep
sequence and visually – video camera LEDs and LED on.
The call lasts max. 1 min. Each touch of the key reinitiates the call.
If the resident answers, the talk mode is activated – LED on. The conversation is hands-free, with a duration of
max. 2 min. If the resident grants the access, it is commanded the opening of the door/ gate and the panel signals
acoustically, with a confirmation beep sequence and visually – LED on.
The door/ gate remains open max. 8 sec.
3. RFID card ACCESS
. Approach the RFID card to the area marked with the
symbol. It is commanded the opening of
the door/ gate and the panel signals acoustically, with a confirmation beep sequence and visually – LED on.
The door/ gate remains open max. 8 sec.