Testing & Commissioning
Safety
Before switching on the mains spur, ensure that the connection is correctly made
and that the cabinet is correctly earthed
as per the section entitled ‘Safety
Information’ on
Page 31 (Inside back page).
Leave the battery disconnected for now. Apply mains power to the control unit and turn on
at the power supply switch.
Basic Functional test
These tests require two people and assume the system is idle, watch out for buttons being
pressed at the other door panel if it is a two door system. When a push-button on the
entrance panel is pressed the associated Phone output LED, on the BSX2 PCB, will
activate and a call cycle will commence with ring voltage being sent to the phone.
Pressing the test button on the active door PCB will cancel the call, otherwise it will
continue to ring for the set time of 30 Seconds or 15 Seconds.
N.B. Pressing the test button when the system is idle will activate the door lock and tone
for 3 Seconds.
So for each phone on the system:-
1.
Call the phone being tested by pushing the appropriate button on the entrance
panel; it should sound loud and clear.
2.
While the phone is ringing Mute can be tested.
For an 801S slide the switch and the ringing stops, put it back.
For a BS-LX press the button, it will flash to indicate ringing and the ringing should
stop, press again to restart the ringing.
3.
Pick up the handset and talk to the person at the panel. Speech should be clear in
both directions. On a BS-LX the Lock button on the phone should now be flashing.
4.
Now press the lock button. The lock release should operate for 3 Seconds (or the
time set on the switches) and then immediately disconnect the call (LED on relay
board goes out).
Other panel functions such as DDA indicators can be checked while testing the phone, to
prove that they indicated at the right moments.
If the there is a second door panel it is only necessary to test it with one phone and carry
out the speech and lock test while observing the DDA indicators, if present. To test the
busy indicator, if present, make a call at one panel and then try and make a call at the
second panel while the first call is in progress. The busy indicator should be on during the
other call and pressing a button should cause a busy tone to be sounded
–
assuming that
the tone volume control is not turned fully down.