BSX Isolated Audio Entry System
PD-142 Issue 1
Installation and Operating Manual
Page 14 of 32
BSX2 Controller Settings
These settings affect only calls etc. for that door PCB. Apart from SW1-
5 both PCB’s in a
two door system should have the same settings. The two doors can have different
settings, though in practice should not as it causes user confusion.
See Page 28 for the PCB layout
Lock Time DIP SW1(1-2)
1 2
Offset
Off Off 3 Seconds*
On Off 5 Seconds
Off On 10 Seconds
On On 20 Seconds
SW1
On
Off
(QWDFGHJK)
Individual Functions DIP SW1(3-8)
SW1
On
Off
(ASERTYUI)
Switch
Function
Comment
DIP SW1-3 Ring Time
Off* = Ring Time is 30 Seconds
On = Ring Time is 15 Seconds
DIP SW1-4 Talk Time
Off* = Talk Time is 60 Seconds
On =Talk Time is 120 Seconds
DIP SW1-5 PCB Select
Off* = This PCB is Door 1, Phones 1-8.
On = This PCB is Door 2 and/or Phones 9-16.
DIP SW1-6
Door contact
type
Off* = Contacts closed when door is open.
On = Contacts open when door is open.
DIP SW1-7 Engage Output
Off* = Power on when other door busy.
On = Power off when other door busy.
DIP SW1-8 Lock type
Off* = Fail Secure Lock.
On = Fail Safe Lock.
*Default setting.
Tone Volume
The tone volume control affects lock and busy tones and can be adjusted as required
including fully off.