background image

Содержание 2960A01M

Страница 1: ... 11 H Speakerphone Option 17 OPTIONAL APPARATUS INSTALLATION 12 I Multillne Service Using 6040 6050 D 180812 Kit of Parts Record Disable and Type Key 18 Dial Intermix 12 6 MAINTENANCE 18 COMPONENT LOCATION AND ACCESS IN FORMATION 13 A Return Procedure 18 A Location of Components 13 B Trouble Analysis 19 B Access of Components 15 C Battery 19 Faceplate Removal 15 D Memory 19 Upper Housing Removal 1...

Страница 2: ...re quired to take whatever measures may Capability to record and automatically dial be required to correct the interference _ 15 telephone numbers of up to 15 digits each 1 02 The reasons for reissuing this section are Last number manually dialed memory listed below Revision arrows are used to em phasize the more significant changes Battery for memory retention in event of ac Show 2960A01M 50 tele...

Страница 3: ...ll dial 1 Record Disable only turns off the record ing must be performed with the handset off ing feature to prevent accidental erasures hook paragraph 5 09 Speakerphone and tip of previously stored numbers party identification options cannot be provided at the same time 2 Record Disable and Dial Intermix same as record disable feature plus the following f Multiline service using adjunct key a All...

Страница 4: ...ble or is in compatible Battery OFF ON switch located on the bot tom of the set Fig 2 should be in the OFF a Amplified receiver G6BM position when set is not in service b Amplified transmitter G7BM D Ordering Guide 2 06 Order as follows c Noisy location GSBM a The 2960A01M telephone set is a modular type d Acoustic or inductive coupling to cus set and may be ordered as follows tomer provided equip...

Страница 5: ...sformer to outlet Handset K2C 50 or K1C 50 MD a Faceplate 260A refer to Table A for color suffix Cord Handset H4I U 50 Cord Mounting D4BU 29 Cord Mounting D4BU 2 _ Cord Mounting D4BU 29 line cord maxi mum 14 feet Cord Mounting D4BU 29 line cord maxi mum 14 feet Cord Clips B for dressing cords as needed Jack Handset 616J lc Replaceable components may be ordered sepa rately as follows Battery KS 203...

Страница 6: ...N503 301 10 i A DIRECTORY DISPLAYED C DIRECTORY PRIVACY WINDOW CLOSED WINDOW CLOSED B DIRECTORY DISPLAYED D DIRECTORY PRIVACY WINDOW OPEN WINDOW OPEN Fig 3 Optional Methods of Installing DirectoryCards Page 6 ...

Страница 7: ...onducting sur premises Cardboard insert shipped with set is faces or other power source does not discarded at time of installation occur If more than one transformer is plugged in to a m ultiple receptacle po veer strip there must be at least one inch sep Dial 35AT3A aration between transformers Only UL listed receptacle power strips with ade Memory 960 type includes button field quate power ratin...

Страница 8: ...on on modular connect ing blocks or adapters refer to Section 503 100 Caution 2 During wiring options care 100 had to be taken that the black BK shield lead remained connected to earth Caution 1 On sets manufactured or ground Sets manufactured or repaired repaired prior to November 1979 to pro after October 1979 will have the black tect the circuit from static discharge the BK shield lead connecte...

Отзывы: