background image

BELL  SYSTEM  PRACTICES 
AT&TCo  Standard 

SECTION  502-541-407 

Issue  3,  June  1973 

SERVICE 

564HK  AND  564HL  TELEPHONE  SETS 

1. 

GENERAL 

1.01 

This section contains connection and maintenance 

information  on  the  564HK  (MD)  and  564HL 

telephone  sets. 

1.02 

This section is reissued to include information 
on  A20B  connector  cable. 

2. 

MAINTENANCE 

2.01 

The  564HK  set  with  D30C  cord  may  be 

subject  to  poor  key  button  illumination  in 

multiple  station,  long  loop  situations  due  to  the 
omission of lamp ground straps on  the  cord plug. 

2.02 

When investigating poor key button illumination 

involving  564HK telephone  sets: 

(a)  If  the  station  termination  is  made  on  a 

66E3-25  or  66E4-25  connecting  block, 

loop-through straps can be installed on connecting 
block  clip  terminals  5, 

11,  17, 

23,  and  29  to  add 

the  necessary  lamp  ground  copper  for  lamps  2, 

3,  4,  and  5.  In  all  cases,  full  pairs  should  be 

brought  to  the  connecting  block  from  connecting 
key  system apparatus via  inside  wiring  or A-type 
connector  cables. 

(b)  If  station  termination  is  made  via  •A20B• 

connector  cable,  or  at  a  3-way  bridging 

adapter,  or  equivalent,  it  is  impractical  to 
field-modify either the plug of the D30C telephone 
set  cord  or  its  mating  connector  on  the  A-type 
connector  cable.  Therefore,  the  564HK  should 
be replaced  with a  564HL. 

2.03 

Remove  and  replace  housing as  follows: 

(1)  To  remove  housing,  loosen  captive  screws 

in  base  of  set.  Lift  housing  up  and  toward 

front  of set. 

(2)  To  replace  housing,  guide  lower  front  of 

housing over pushbuttons, align housing with 

base  of  set,  and  gently  press  housing  into  place. 
Tighten  captive screws  in  base of set. 

2.04 

Replace  cracked  pushbuttons  or  collars. 
Remove accumulated dirt or film from lamps, 

collars,  and  pushbuttons  with  a  water  dampened 

cloth. 

DO  NOT  USE  SOL VENTS  OF  ANY 

KIND. 

If  cleaning  does  not  correct  binding  of 

pushbuttons, replace  button and  collar  assembly. 

2.05 

Maintenance  of  handsets,  dials,  and  ringers 

is  outlined  in  sections  covering  these 

components. 

2.06 

When  replacing  a  defective  lamp  use  a 

KS-6320  orange  stick  to  extract  the  lamp 

from  its  socket,  and  install  the  new  lamp  with  its 

contact  surfaces  properly  aligned  with  the  lamp 

socket. 

2.07 

Maintenance  of  the  636-type  key  consists  of 
cleaning  contacts  with  a  265-type  tool,  and 

checking for loose or  broken connections. 

It 

No  field  m aintenance  sho uld  be 

performed  on  the plug  of plug-ended 

mounting cords. 

2.08 

Replace  set  if  the  following  requirements 

cannot be met: 

(a)  When  depressed  locking  plunger  should,  on 

its downstroke,  release any previously locked 

plunger. 

(b)  When  any  pushbutton  plunger  is  released 

from  its  operated  position,  it  should  return 

with a  snap  to  its nonoperated  position. 

(c)  An  operated  key  plunger  should  not  release 

during  downstroke  of  hold  button. 

(d)  An operated key plunger should release from 

its  operated  position  on  the  upstoke  of  the 

hold  button. 

©  American Telephone and Telegraph Company, 

1973 

Printed in U.S.A. 

Page  1 

SSP 

502-541-407-i03_1973-06-0Ljpg  Scanned  by  Frank 

Harrell, 

(Cowboy  Frank) Castle Rock,  Colorado  Feb 02,2012  19:08:56 

Содержание 564HK

Страница 1: ...of set 2 To replace housing guide lower front of housing over pushbuttons align housing with base of set and gently press housing into place Tighten captive screws in base of set 2 04 Replace cracked pushbuttons or collars Remove accumulated dirt or film from lamps collars and pushbuttons with a water dampened cloth DO NOT USE SOL VENTS OF ANY KIND If cleaning does not correct binding of pushbutto...

Страница 2: ...ephone sets are factory equipped with a KS 20419Ll 10 volt AC only buzzer Page 2 3 03 Current models of the 564HL telephone sets are furnished with the HlB ringer 3 04 Red and black ringer leads are factory wired to terminals RR and RT Refer to notes in Fig 3 for ringer connections when bridged ringing on a particular line is desired BSP 502 541 407 i03_1973 06 02 jpg Scanned by Frank Harrell Cowb...

Страница 3: ...te or intercommunicating lines with the signal key common to each line The signal key under con trol of the line switch will operate the signal circuit of each line when associated pickup key is depressed Use S lead on 2nd 3rd or 4th pickup key as required Notes 1 All convertible key positions are arranged in the factory as pickup positions To con vert a key position from pickup locking to signali...

Страница 4: ...E HIA RINGER AS FOLLOWS BK TO RT S TO K OF NETWORK S R TO A OF NETWORK R TO RR 2 IF CAPACITOR IS NOT REQUIRED IN RINGER CIRCUIT MOVE S RINGER LEAD TO A TERMINAL FOR HIA RINGER OR R RINGER LEAD TO A TERMINAL FOR HIB RINGER 3 FOR BRIDGED RINGER SERVICE MOVE R AND BK RINGER LEADS TO RING AND TIP RESPECTIVELY OF LINE INVOLVED TO SILENCE RINGER INSULATE OR STORE R AND BK LEADS ON A AND K TERMINAL OF NE...

Отзывы: