Error Events
4-28
Installation, SPM, Maintenance, and Troubleshooting Supplement
Current Event
4
The Current error event reports error statistics for the 15-minute interval which
is currently active. Because intervals are not synchronized with the system
clock, the Elapsed minutes line displays the number of minutes that have
elapsed for the current interval. The number of minutes reported is rounded to
the nearest minute and can be a value between zero and 15.
From your system programming console, use the following sequence to access
the Current screen (be sure to select the corresponding 100R INA or 100 DCD
module slot number).
Menu:
Maintenance
→
Slot
→
Slot#
→
Enter
→
Error Events
→
Current
Interval Event
4
The Interval error event reports error statistics for a specific 15-minute interval
from the past 24 hours. There are 96 15-minute intervals in a 24-hour period
segment. Interval one is the most current and interval 96 is the oldest. From
your system programming console, use the following sequence to select an
interval number from the Interval screen (be sure to select the corresponding
100R INA or 100 DCD module slot number).
You can refresh the Current screen by pressing
Back
and then
pressing
Current
again.
Содержание Lucent Technologies MERLIN MAGIX
Страница 2: ......
Страница 6: ......
Страница 12: ......
Страница 24: ...PCMCIA Translation Card 1 12 Installation SPM Maintenance and Troubleshooting Supplement ...
Страница 162: ...Installing the E911 Adjunct 6 8 Installation SPM Maintenance and Troubleshooting Supplement ...
Страница 178: ...PCMCIA Upgrade Card 7 16 Installation SPM Maintenance and Troubleshooting Supplement ...
Страница 266: ...Flow Control 8 88 Installation SPM Maintenance and Troubleshooting Supplement ...