Configuration Rules
Issue 4.0 October 1996
4-3
Configuration Rules
These rules determine what hardware is required for the set of features
requested by the customer.
■
Six channels of analog tip/ring (T/R) service can be provided per IVC6
(AYC10) circuit card. Up to three cards are allowed providing a maximum
of 18 channels. However, additional memory is required before the third
card can be installed.
■
Switch Administration (System Programming and Maintenance Utility) is
required for all MERLIN LEGEND configurations. It requires the COM1
(tty00) serial port.
■
Remote customer access requires one or more asynchronous ports. To
accommodate this, a multi-port serial card may be required.
The maximum number of simultaneous asynchronous ports that can be
active for remote administration and maintenance by the customer is
three.
Use the serial port, COM1 - tty00, as the first customer remote access
port. Use the multi-port serial card for the additional two remote access
ports.
■
For systems using Lucent Intuity Lodging, the Property Management
system (PMS) automatically configures the first available serial port other
than COM2 as the PMS link port.
NOTE:
Remote administration for the customer is available as a separately
ordered package that includes modems, the UNIX System V
Release 4.2 Multi-user package (if not already purchased for
networking), and a multi-port serial card (if not already purchased for
SID switch integrations).
■
One remote access port, COM2, and a modem must be dedicated for
remote maintenance (optional for MERLIN LEGEND).
■
The serial port, COM2 - tty01, is reserved for the remote maintenance card
or may be used for remote access with a modem. COM2 is reserved for
Lucent Technologies remote maintenance.
NOTE:
The remote maintenance card is optional for MERLIN LEGEND,
COM2 may be free for other applications.
The internal modem will be used in the United States. International sales
require a separate modem.
■
Lucent Intuity Call Accounting System (if configured) requires one serial
port. Depending on the configuration, this may use COM1 or the multi-port
serial card.
Содержание Lucent Technologies INTUITY MAP/5
Страница 1: ...INTUITY MAP 5 Hardware Installation 585 310 146 Comcode107856882 Issue 4 October 1996 ...
Страница 11: ...Contents Issue 4 0 October 1996 xi ABB Abbreviations ABB 1 GL Glossary GL 1 IN Index IN 1 ...
Страница 12: ...Contents xii Issue 4 0 October 1996 ...
Страница 50: ...Getting Started 2 4 Issue 4 0 October 1996 Figure 2 1 How to Hold a Short Circuit Card ...
Страница 76: ...Connecting Peripherals and Powering Up 3 20 Issue 4 0 October 1996 ...
Страница 89: ...Removing the Front Panel Issue 4 0 October 1996 5 5 Figure 5 1 Removing the MAP 5 Front Panel Tab slots Tabs ...
Страница 94: ...Getting Inside the Computer 5 10 Issue 4 0 October 1996 ...
Страница 100: ...Installing Circuit Cards Introduction and Types 6 6 Issue 4 0 October 1996 ...
Страница 104: ...Installing Tip Ring Circuit Cards 7 4 Issue 4 0 October 1996 ...
Страница 138: ...Installing Optional Hardware 10 18 Issue 4 0 October 1996 ...
Страница 146: ...Finishing Up 11 8 Issue 4 0 October 1996 ...
Страница 150: ...Component Ordering Numbers A 4 Issue 4 0 October 1996 ...
Страница 184: ...Cable Connectivity B 34 Issue 4 0 October 1996 ...
Страница 266: ...Index IN 6 Issue 4 0 October 1996 ...