INTRODUCTION
Thank you for purchasing a Belkin Uninterruptible Power Supply
(UPS). Each year, several natural and man made occurrences put
the power supplied to your electronics in your home or office in
jeopardy. At risk are your hardware, software and data because of
these power problems.
IMPORTANT SAFETY INSTRUCTIONS
Please save this manual!
It contains important operating instructions and warranty information
pertaining to your UPS.
Please save or recycle the packaging materials!
The UPS packaging was designed with great care to provide
protection during shipment and delivery. These materials are
invaluable if you ever have to return the UPS for service. Damage
sustained during transit is not covered under the warranty.
Federal Communications Commission Interference Statement
This equipment has been tested and found to comply with the limits
for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications. To assure continued
compliance, use only shielded interface cables when connecting to
computer or peripheral devices. Any changes or modifications not
expressly approved by the party responsible for compliance could
void the user’s authority to operate this equipment.
CONTENTS
You should have received the following:
1 – UPS unit
1 – Sentry Bulldog Shutdown Software
1 – USB Cable
1 – Phone Line Cable
UPS FEATURES AND FUNCTIONS
Before installation, please inspect the UPS upon receipt. Make sure
that nothing is damaged.
Your UPS features 3 LED indicators. Each is marked by a power
icon; please familiarize yourself with this chart, as it will assist you in
the use of your UPS.
Chart 1
ALARMS
Back Up (Slow Alarm)
When in “BACK UP” on battery mode, the RED LED illuminates and the
UPS sounds an audible alarm. The alarm stops when the UPS returns to
LINE NORMAL operation.
Low Battery (Rapid Alarm)
In “BACK UP” mode, when the battery energy runs low, the UPS beeps
rapidly until the UPS shuts from a depleted battery or returns to LINE
NORMAL operation.
Fault (10 Seconds Continuously)
When the output is shorted, the UPS emits a 10 seconds continuously
alarm to warn of a short condition. Disconnect the equipment prior to
checking the equipment.
FRONT PANEL
Diagram 1
1.
UPS Outlets (See #1 on Diagram 1)
These outlets are your battery back up outlets. We strongly
recommend that only sensitive equipment such as your computer and
monitor should be plugged into these outlets.
Caution: Never
connect a laser printer or scanner to the backup outlets of UPS
with other computer equipment. A laser printer or scanner
draws significantly more power when in use than when sitting
idle. This may overload the UPS.
Should a power outage occur, your battery backup would
automatically turn on. Power (utility or battery) is not supplied to these
outlets when the UPS is switched off.
Do not plug any surge protectors or power strips into the battery
back-up outlets (i.e. daisy chaining).
2.
SURGE Protected outlets (See #2 on Diagram 1)
These outlets do not provide power during a power outage.
Equipment such as computer peripherals, printers, fax machine’s, or
a desk lamp may be plugged into these outlets. The On/Off button
does not control these outlets.
3.
The On/Off button has 3 functions:
1. Turns on the UPS. Depress button at least 2
seconds. The green light will come on.
2. Cold Start function. Assuming the battery is
charged the UPS will work without it being
plugged into an outlet. Depress and hold the key
for at least 2 seconds to turn on the UPS. The
3. Silence function. During “On Battery Mode”, the
audible sound can be turned “ON” or “OFF” by
depressing the switch.
Side Panel A
AC Input
Circuit Breaker
IN
Push to Reset
Refer to Bottom for
Cautionary Markings
Phone/Fax
Modem
Protection
OUT
OUT
1
2
3
Diagram 2
4.
AC Input Power Cord (See #1 on Diagram 2)
Provides power to your UPS.
5.
Phone/ Fax/ Modem Surge Protection (See #2 on Diagram 2)
The Phone/ Fax/Modem lines are surge protected. There is one input
jack and two output jacks. This allows you to split one telephone
connection to two separate devices.
6. AC Breaker (Circuit Breaker; See #3 on Diagram 2)
Should a power overload occur, the circuit breaker would trigger the
UPS to turn off AC power. In order to restore the power, depress the
circuit breaker button to reset, then depress the Power button.
Side Panel B
Diagram 3
7.
Your UPS features a USB communication port. Installation of the
cable and software is optional. This allows the UPS to connect to you
computer. The Sentry Bulldog Software will not work if the UPS is not
connected to you computer. This does not mean the battery backup
feature will not work without the software and cable installed. The
UPS will still provide backup power but you will be unable to utilize
the data management capabilities of the software.
INSTALLATION
Note!
Before installation, please inspect the UPS Upon
receipt. Make sure that everything inside the package
is not damaged.
Connect to AC Utility Power
Connect the AC inlet to utility power via the power
cord. Please make sure there are no devices
plugged into the UPS unit. Check to see if the “Site
Wiring Fault” indicator is lit or not. If it is lit, please
have the utility wiring inspected by an electrician.
Charging the Battery
For best results, charge the battery for 6 hours prior
to initial use. The UPS charges its battery whenever
it is connected to the utility power. Should you see
the red battery light come on, the battery may need
immediate charging.
Turning on the UPS
Turn on your UPS by depressing the On/Off button for
approximately 2 seconds. You will see the green indicator light come
on.
Plug in Power Devices
Plug your devices into the AC outlets on the top of the UPS. To use
the UPS as a master on/off switch, make sure all of the loads are
switched on.
Caution: Never connect a laser printer or
scanner to the backup outlets of UPS with
other computer equipment. A laser printer or
scanner draws significantly more power
when in use than when idles. This may
overload the UPS.
Connect the phone/ fax/ modem lines
Connect a single phone / fax/ modem line into the surge protected
sockets on the right of the UPS. The RJ-11 modular sockets accept
standard single line telephone connections.
Plug one end of the phone cable you received into your telephone
wall jack and plug the other end into the jack marked IN. You may
now plug a phone, fax or modem into the two jacks marked OUT.
(See Diagram 4)
Phone
Modem
/ Fax
To Telephone Socket
Diagram 4
Note:
This connection is optional but highly suggested as phone /
fax / modem lines often carry dangerous surges and spikes. The
UPS works properly without a phone / fax/ modem connection.
Caution: The phone/fax/modem protection feature could be
rendered inoperable if improperly installed. Make sure that the
telephone line from the wall is plugged into the connector marked
“IN”, and the devices to be protected (phone/ fax/ modem) are plugged
into the connector marked “ OUT”.
USB (Universal Serial Bus) Communication Port
A USB port is provided to relay the signal to support DOS,
WINDOWS, and the other operating system.
Communication port
(Optional) To fully utilize the Sentry Bulldog Shutdown Software; you
will need to connect the UPS to your computer. Connect the USB
cable to your UPS then connect the other end to the USB port on
your computer.
Software Installation (Optional)
Compatible with any computer running the following:
95/98/ME/NT4/2000/XP & Novell 3.X & Higher
1.
Your UPS features the Sentry Bulldog Shutdown Software.
This allows you to protect and save your data should a power
outage occur, as well as safely shutdown your computer in your
absence. This software is compatible with Windows
95/98/ME/NT4/2000/XP and Novell 3.X & higher.
2.
To install the software, please place the CD into the CD drive of
your computer.
3.
Your computer should automatically run (AutoPlay) the CD. If
this does not occur, go to the Run feature on your Start icon
(lower left corner) on your screen. Please enter the CD drive, it
may be D: Should you continue to have a problem, please refer
to your computer’s owner’s manual for the correct drive. Upon
entering the drive Run setup.exe. to execute the software.
4.
Once uploaded, please click the Bulldog icon on the screen.
5.
Click Install Belkin Sentry Bulldog for Win
95/98/ME/NT4/2000/XP
6.
InstallShield Wizard will appear onscreen, click Next.
7.
Please read the License Agreement and click Yes.
8.
On Setup Type, click ALL (Standalone). You should not install
the networking files unless you are technically qualified to use
these features. For more information on networking, please
refer to the software user’s manual. The software user’s
manual can be downloaded from the user’s manual icon.
Indicator Condition
Description
ON-LINE
- Solid green
AC power is on
ON-BATTERY
and
LOW-BATTERY
- Flashing Red
LED with Audible
Alarm (Beeping)
This condition for the
On-Battery and
Low-Battery LED can
indicate 1 of 3 problems:
1. The UPS is on battery
backup and an
intermittent audible
alarm is on. The UPS
will begin shutdown
procedure.
2. Battery is low. The UPS
will start shutdown. The
buzzer sounds an
audible alarm.
3. There is a problem with
the UPS. The LED will
be lit continuously and
the buzzer will sound
audible alarm for 10
sec.
SITE WIRING
FAULT
- Solid Red
The Site Wiring fault LED
can indicate 1 of 2 possible
conditions:
1. Open or high resistance
on the ground line
2. Hot or neutral polarity
circuit
*Note in order for your UPS
to work properly, you must
have a properly grounded
AC circuit. If your Site
Wiring Fault LED is lit,
please contact an
electrician to properly wire
this circuit.
F6H350-USB
F6H500-USB
F6H650-USB
○
○
○
○
R
2
22
2
1
11
1
3
33
3
USB Communication Port
Battery Light
Laser Printer
Battery Light