background image

NV9640A

NV9000 Control Panel

User’s Guide

UG0072-01

30 Apr 2013

Содержание Miranda NV9640A

Страница 1: ...NV9640A NV9000 Control Panel User s Guide UG0072 01 30 Apr 2013 ...

Страница 2: ...of the Software Product are owned by Miranda Technologies Inc The Software Product is protected by copyright laws and internationaltreatyprovisions Customershallnotcopytheprintedmaterialsaccompanying the software product The software contains proprietary information of Miranda Technologies Inc It is provided under a license agreement containing restrictions on use and disclosure and is also protec...

Страница 3: ... for operators and service personnel Specific warnings and cautions appear throughout the manual where they apply Please read and follow this important information especially those instructions related to the risk of electric shock or injury to persons Restriction on Hazardous Substances RoHs Miranda is in compliance with EU Directive RoHS 2002 95 EC governing the restricted use of certain hazardo...

Страница 4: ...instruc tions or on the equipment Always refer fuse replacements to qualified service person nel To avoid explosion do not operate this equipment in an explosive atmosphere Have qualified service personnel perform safety checks after any service The lightning flash with arrowhead symbol within an equilateral triangle alerts the user to the presence of dangerous voltages within the product s enclos...

Страница 5: ...s at all times when handling this equipment This product should only be powered as described in the manual To prevent equip ment damage select the proper line voltage on the power supply ies as described in the installation documentation To prevent damage to the equipment read the instructions in the equipment manual for proper input voltage range selection Some products include a backup battery T...

Страница 6: ...vi ...

Страница 7: ...n 10 Installing Software and Documentation 10 Initialization 11 Testing 12 4 Configuration 13 Summary 13 Adding a Panel to an NV9000 Configuration 14 NV9640A Panel Configuration Page 16 Regions of the Configuration Page 17 Configuration Tasks 17 Commitment Buttons 18 Panel Options 19 Checkbox Options 21 Button Definitions 23 Button Specification 24 Button Types 25 Edit Navigation Button Dialog 31 ...

Страница 8: ...fix Templates 43 Template Changes 43 Composing Navigate Templates 44 Template Changes 44 5 Operation 47 Summary 47 Modes of Operation 48 Button Legends 48 Levels 49 Level Mapping 50 Virtual Level Expand and Contract 50 MD Devices 50 Lists 51 Operating Concepts 51 Levels 51 Breakaway 52 Level Grouping 52 Hold 52 Breakaway 52 Multi Destination Mode 53 Category Selection 53 Buttons 54 Back 54 Broadca...

Страница 9: ...akes 67 XY Mode 67 Single Destination Panel 67 MD Mode 67 Name Sets 67 Broadcast Routes 68 Making Broadcast Routes 68 Removing Broadcast Routes 68 Data Routing 69 Automatic Data Routing 69 Manual Data Routing 69 Semi Automatic Data Routing 69 Chop 70 Salvo Mode 70 Menu Mode 70 Software Versions 71 User 71 Panel 72 LCD Control 72 Setup Mode 73 6 GPIO 75 The Interface 75 Input 75 Output 76 GPIO Conf...

Страница 10: ...x Table of Contents Environmental Specifications 83 Defaults 83 Initial Panel State 83 Configuration Page 83 DHCP 84 Drawings 84 8 Misc Topics 89 LCD Buttons 89 Ordering Information 89 Index 93 ...

Страница 11: ...ors primarily Chapter 6 GPIO describes the tally a k a GPIO interface and tells you how to configure it Chapter 7 Technical Details provides electrical mechanical and environmental specifica tions product drawings and default settings Chapter 8 Misc Topics presents a glossary and miscellaneous instructions and information An index and glossary are also provided for your reference The PDF Document ...

Страница 12: ...re used throughout this guide The term control panel refers to the NV9640A control panel and to NV96xx control panels in general High tally means that a button is brightly illuminated Low tally means that a button is illuminated at low intensity Most buttons assume a low tally state until selected MD is an abbreviation for multi destination SE is an abbreviation for NV9000 SE Utilities Other Docum...

Страница 13: ...s It can operate in X Y mode or in multi destination MD mode Operators can switch between modes at any time This 2RU panel is organized as shown in figures 2 1 and 2 2 Fig 2 1 NV9640A Front At the rear in addition to power serial and network connectors is a 25 pin GPIO tally connector that supports 4 optically isolated relay outputs and 8 optically isolated inputs Fig 2 2 NV9640A Rear 1 An equival...

Страница 14: ...lly can be either medium or high bright ness and low tally can be either low or medium brightness High tally is always constrained to be brighter than low tally See LCD Buttons page 89 for a color chart Although you can see a list of the pages in the tree during configuration the structure of the tree is not evident on the panel itself The panel operator must commit the tree structure to memory to...

Страница 15: ...ned in the NV9000 configuration Operators might need to scroll to see or select a destination Status The status column indicates what source was routed to the destination In X Y mode the status column represents the levels of a source or the levels of multiple sources under breakaway These are called the current source s The presence of in the status or preset columns means that that particular le...

Страница 16: ...or system mnemonics for devices depending on 1 the state of the Name Set Toggle button if the panel has one 2 the default name set 3 the existence of name sets in the NV9000 configuration An alias is a name defined in a name set Flags The display also shows flags of different kinds next to the sources and destinations Selection Marks At the far right of the display are marks 3 small bars that turn...

Страница 17: ...s and sources You can scroll through destination lists using the Up and Down buttons Select a destination using selection buttons choose a source and repeat for all desired routes Then press Take Takes are all level and breakaways cannot be performed S A Hold button allows you to select many MD destinations at once Single destination mode Single destination mode is not a distinct mode but we menti...

Страница 18: ... pre defined or default state Hold breakaway levels System salvos Lock protect release for destinations Forced release of locked or protected devices Device selection using indexes or suffixes The NV9640A provides the following additional features The NV9640A supports multiple level breakaways in X Y mode This lets you route multiple sources to the same destination on different levels The panel su...

Страница 19: ...hnical support Refer to Miranda Technical Support on page 101 Depending on your order the NV9640A items that can ship include One or more NV9640A control panels One or two power supplies for each NV9640A with straps that secure the AC power cords to the power supplies Optional WC0053 breakout cable The package does not contain network cables serial cables or mounting screws You do not need to take...

Страница 20: ... There is only one way they fit Do not force them Then connect the power supply to AC power A second power connection is for redundancy only protection against failure and is not a requirement for operation Refer to Power Specifications on page 81 for details on the PS0001 power supply 4 Connect tally GPIO input devices and output devices at the DB25 GPI connector You can use the optional WC0053 b...

Страница 21: ...om row of buttons Press the digits of your intended panel ID in order up to 8 digits Then press the Save button on the right to save the ID or press the Cancel button to discard the ID The new panel ID does not appear until you exit the menu after saving 5 You may use any other menu function at this time When you are finished press the exit but ton which reappears to leave the menu 6 After you des...

Страница 22: ...inue to see No Server Acquiring IP Address or Locating Network on button 2 you have a problem Reboot everything and try again S The NV9640A by default acquires its IP address through DHCP on the panel router network of the system controller You can use the Panel IP Configuration Utility to force the panel to have a static IP address If in setup mode you do not see your designated panel ID on the t...

Страница 23: ...s is not limited in size Panel operators navigate to different button pages to perform different tasks We say that the user interface is tree structured or hierarchical although it is not always a tree in the strictest sense You can construct a tree like graph of the button pages The NV9640A in addition has an 8 42 alphanumeric display that presents the status of opera tions as they occur An NV964...

Страница 24: ...guration After launching NV9000 SE Utilities choose Control Panels from the Configuration pane in the navigation area The Control Panels configuration page appears Click Add Control Panel at the bottom of the configuration page The Add Control Panel page appears Choose NV9640 from the Type field In the ID field enter the panel ID you assigned to the panel while it was in setup mode Give a name to ...

Страница 25: ...sing either of these buttons creates a button page template not a panel configuration See Global Navigation on page 40 Return to the Control Panels page to view your new entry To edit an NV9640A configuration either double click its list entry or select the entry with a check in the checkbox and then click Edit Selected Control Panels You will then see the panel configuration page for the selected...

Страница 26: ...e 40 After you configure buttons and button pages the appearance of the panel buttons will have changed At the bottom of the page are two important configuration buttons Revert to Saved and Save The Save button commits modifications you have just made The Revert to Saved button restores the last saved version of the panel configuration canceling any changes you just made Button Definition Section ...

Страница 27: ... following Button page table This section the region below the button definition section displays a list of the individ ual pages of the tree structure The button page at the top of the list or root of the tree is called Default During operation category buttons can display device subpages when pressed Those sub pages are not definable in NV9000 SE Utilities The button page list does not display t...

Страница 28: ...button on each subpage The back button causes the NV9640A to redisplay the previous page Place a Navigate button on each page where the navigate button causes the NV9640A to display a specific page S The operator can always return from system generated pages e g device lists using the back button The panel operator in most cases needs a Take button and at least one selection button In addition to ...

Страница 29: ...ns as the multi destination device limit These are its drop down menu options Default Mode X Y Mode Starts the panel in XY mode after a reset See Defaults on page 83 Multi Dest Mode Starts the panel in multi destination mode after a reset Release Mode Normal Release This panel can release locks and protects set by the designated user at this panel or any other panel Force Release This panel can re...

Страница 30: ...rol port that is in use the operator must first free the port by performing a tristate take on the port that is taking the device as a source to itself as a desti nation on the control level A take can occur on the machine control level if in the status col umn of the display the source entry is FREE MD Data Routing Mode Automatic If a machine control i e data level is involved in a route the sys ...

Страница 31: ...Preset mode active when the panel reverts to its default state after a Default State button is pressed or when the panel is restarted S A Save Preset button is needed only when you want the operator to be able to view or change the mode Default Name Set System Name A list of name sets appears in the drop down menu The name sets can be defined under the System Management pane of NV9000 SE Utilities...

Страница 32: ...urces not configured on this panel Causes the names of source devices that are not presently configured for this particular panel to be effectively hidden When another panel changes the source to one not config ured for this panel this panel displays asterisks instead Deselect all destinations and turn off hold after take After selecting many MD destinations with Hold mode on it can be time consum...

Страница 33: ...is type of button additional selec tions are needed to complete the button configuration Special functions such as Navigate and Back These functions allow the panel operator to move from one button page to another The Navigate button is unique it initiates a dialog in which you create a subtree System generated button functions These are buttons that are generated dynamically by the router control...

Страница 34: ... Some buttons do not allow you to enter button text Category buttons for example use the category mnemonic as the button text Button Color A pull down menu where you can select a button color amber blue green grey purple red or yellow Each of the 7 defined colors has two brightness levels Note in usage buttons are dark if their functions are disabled Buttons are low tally if they are available But...

Страница 35: ...tions vary from button type to button type There are other button definition options that become available when you are defining a cate gory button or a global navigation button and you have defined one or more suffix pages or global navigation pages These options are described under Global Navigation on page 40 The Navigate button is a special case It invoking an Edit Navigate Button dialog durin...

Страница 36: ...est system timing Clear Preset Erases preset entries while leaving the panel in the same mode We recommend you use this button because it is a safety feature The clear preset button has the side effect of switching off Save Preset mode Default State Returns the panel to its most recent power up state That is called the default state Destination Selects a destination When you assign a destination b...

Страница 37: ...ion about level mapping and perhaps other matters The operator presses the information button once to see the information and again to hide the information Level Map Cross connects levels in the same physical router The function is typically used to shuffle audio channels for example to connect AES1 2 to AES3 4 The Level Map mode is cancelled when the next normal take is performed involving the se...

Страница 38: ...st Page Up also scrolls through multi destination devices in multi destination mode and through levels in X Y mode When the operator is displaying a list of devices from a category the Page Up button will return the operator to the page containing the category button Panel Lock Prevents accidental changes to the panel settings especially router crosspoints When the panel is locked the button array...

Страница 39: ...election buttons the Page Up and Page Down buttons activate and the operator can scroll through the destinations See Selection Buttons on page 35 for further detail During configuration when you assign a selection button two additional drop down menus appear Display Index and Multidst Device The drop down menu for the button s display index has as many entries as the current page has selection but...

Страница 40: ...inactive On the actual panel it will remain unlit dark VFD SEL Toggle The button is toggle In one state it makes the display VFD scroll when the operator presses Page Up or Page Down In the other state it makes the items on selection buttons scroll The selection buttons represent levels when the panel is in X Y mode and represents destinations in MD mode Thus there are 3 scrolling options Scroll t...

Страница 41: ...endent of the page name You can change either without affecting the other Virtual Level Expand In X Y mode this button causes the alphanumeric display to show virtual levels at the lowest level of grouping with the most detail The button affects only virtual levels that have been grouped See Level Grouping on page 52 The button has no effect in multi destination mode This button has no configurati...

Страница 42: ...n where you can reorder the list items as you wish See Automatic Fill Options following Automatic fill creates as many new pages in the button tree as required to support the num ber of fill items If the number of items is greater than 29 SE places 28 items on a page where the bottom left button is a back button and the bottom right button is a forward button The last page of the automatic fill wi...

Страница 43: ...are included in the list S If you leave the Starting with field blank the page s will create Src Dst buttons for all source devices Manually Fill Devices Specify the number of buttons you want to be assigned The soft ware creates as many subpages as are required to hold the buttons The buttons are Src Dst buttons but remain blank so that you can assign sources and destinations to them manually Sal...

Страница 44: ...tton page This is a sample of a button page list It represents this tree structure You can change the name of a page by double clicking the page s name field and editing its text Changing the name of a page does not cause a change to the caption of the navigation button and vice versa During configuration you will use Navigate buttons to create new pages During configuration you can double click a...

Страница 45: ... many functions not the least of which is to provide feedback e g source and destination mnemonics on the face of the buttons when the operator is performing takes Selection buttons support level selection in XY mode and device selection in multi destination mode You should configure at least one selection button for feedback You may configure as many selection buttons as are suitable for your sys...

Страница 46: ...scroll through the levels MD Mode When the panel is in MD mode a set of selection buttons presents a set of MD devices If a selection button is blank an MD device was not assigned to it If a selection button is high tally the MD device is selected If a selection button is low tally the MD device is not selected Perform MD destination population by clicking lines in the image of the display and scr...

Страница 47: ...e preset the operator then presses Take In hold mode the MD devices remain selected after the take Configuration You can configure selection buttons on any of your button pages During configuration when you assign a selection button an additional drop down menu appears Display Index The drop down menu for the button s display index has exactly 8 entries one for each line of the alphanumeric displa...

Страница 48: ...of those need be used Those that are not used are considered undefined S It is possible to have duplicate entries in the MD destination set For example it might be useful to have one or two MD destinations available at all times Multi destination configuration uses the display portion of the panel graphic in the panel configuration page It also uses Page Up and Page Down buttons also in the panel ...

Страница 49: ...diately above whatever MD destina tion you have highlighted on the right The Replace button replaces whatever MD destination you have highlighted on the right with the selected destination from the left The Remove button removes highlighted MD destinations from the right At the bottom left there is a scroll box in which you can adjust the maximum number of MD destinations The page size is indicate...

Страница 50: ...vigation pages are templates patterns that may be used and reused in the creation of NV9640 configurations There are two types of global navigation pages Suffix and Navigate A navigate template may define a single button page or an entire subtree of pages A suffix template is a single page only The buttons allowed in a suffix template are a small subset of the buttons supported by NV9640A configur...

Страница 51: ...Template Suffix pages can be accessed through Category buttons When you create a Category button the button type region displays a checkbox option Use global suffix page to select devices When you check the option an additional Suffix Page field appears Choose one of the suffix templates in the drop down list The suffix page appears in the panel configuration s button page list Navigation Template...

Страница 52: ... can be used for both source and destination categories If you do not check the Use global suffix page to select devices box the category button produces during operation a list of all the devices in the category on one or more button pages You cannot view those dynamically created button pages in NV9000 SE Utilities Referencing a Navigate Template Navigate pages can be accessed through Global Nav...

Страница 53: ... displayed then after the operator presses two numerals all further entry is disabled S It is logical to include a Take button on suffix templates used by source categories It is not logical to include a Take button on suffix templates used by destination categories However if a suffix template can be used for either sources or destinations then a Take button is at your discretion The operator can...

Страница 54: ...e template is not substantially different from composing panel configura tions The only difference is that navigate templates do not have Global Navigation buttons Usage differs however Navigate templates can be referenced by panel configurations And that is the point you can create multiple panel configurations that because they reference a navi gate template can all be guaranteed to include the ...

Страница 55: ...on software adjusts all panel configurations to use the modified navigate template If you want to update the global navigation page in only some of your panels create an alter nate version of your navigate template and change the panel configurations to use one or the other as desired ...

Страница 56: ...46 Configuration Global Navigation ...

Страница 57: ...nstallation It is impossible to describe operations in great detail because there is no one interface What we can do however is give you general advice and of course specific information on the behavior of the different button types and opera tional modes Because some of the panel s buttons can have arbitrary legends a button s legend might or might not indicate its function Operators and configur...

Страница 58: ...mode A single destination is defined during configuration You have only to choose a quick source The take is automatic when you are using quick sources Single destination mode is not a distinct mode and actually need not involve only a single destination It can be combined with X Y mode or multi destination mode Secondary modes are Setup mode where the NV9640A is freshly powered up but disconnecte...

Страница 59: ...he display do not scroll 3 Scrolling both the display and the selection buttons at the same time This behavior can occur only when the panel has no VFD SEL Toggle button If the panel has a VFD SEL Toggle button you can switch between options 1 and 2 The button will read either Paging VFD or Paging Sel Buttons When you scroll the selection buttons they scroll modulo the number of buttons For instan...

Страница 60: ...evels for a particular device belong to a virtual level group you can collapse the display of levels to its minimal possible representation just the group names or expand the display of the levels so that all individual levels are displayed Use the Virtual Levels Contract button to collapse the list of levels Use the Virtual Levels Expand button to expand the list of levels See Level Grouping on p...

Страница 61: ...n move to the next set of entries in the list by pressing the forward button Press the back button to go to the previous set A final back returns to the page containing the button that displayed the list Levels or MD devices presented on the display are also list entries To scroll through lists of levels or MD destinations use the Page Up and Page Down buttons Operating Concepts Status for most or...

Страница 62: ... The two video levels are grouped under Video The groups Mono and AES are also grouped under Audio The levels Video Audio Mono and AES are abstract levels the other levels e g HD are basic levels If you have chosen a destination whose basic levels are grouped the panel s display can show either the top abstract levels or it can show the basic or bottom most levels A Virtual Levels Expand button if...

Страница 63: ... The panel displays a suffix page which contains a keypad containing numerals and possi bly alphanumeric suffixes and perhaps some other functions By pressing keys of the key pad you can construct a device name Each press of the keypad appends a digit or a suffix to the category name The device name appears in the alphanumeric display as you con struct it Suffixes may be numeric or alphanumeric an...

Страница 64: ...edisplay the previous button page The previous buttons become active A back button may have any legend and be any color but typically its legend is just BACK and typically its color is blue as for back buttons generated automatically for lists A back button is never high tally A back button has no effect on the contents of the alphanumeric display See also Forward Broadcast A broadcast button appl...

Страница 65: ...e within the category If you make a mistake press the Clear Preset button and try again When you have finished entered an index or suffixes press either the back button or the take button if present The panel will have tracked your entries by concatenating the index or suffixes to the current destination name for a destination category or to a preset source name for a source category While you are...

Страница 66: ...n which case the destinations buttons are generated dynamically In either case you navigate through multiple pages by pressing the back and forward buttons The button text is normally the destination name but the configurer can give it any text Dynamically generated destination lists however use the device names defined in the NV9000 configuration Destination names are often created as a concatena...

Страница 67: ... protected destination directly You must first unlock it The Destination Protect button text is normally Dest Protect and when a selected MD desti nation is protected the button legend becomes Dest Unprotect MD Mode In MD mode a protected destination has a P next to it when it appears in the display When you select a protected MD destination with a button the Destination Protect button goes high t...

Страница 68: ...nation button at a time When you select a source the source applies to all selected high tally destinations If hold is still on when you press Take the selected destinations remain selected and the display reflects the selected destinations The buttons for the selected destinations remain high tally Without hold enabled the panel has no destinations selected after an MD take and the buttons for th...

Страница 69: ...AUDIO 4 TIMECODE TIMECODE Page 1 Page 1 Preset Status Level Dest X Y HD X Y HD Dest CAM 14 CAM 1 SD Dest CAM 14 CAM 1 SD VTR 1 CAM 14 CAM 1 AUDIO 1 VTR 1 CAM 14 CAM 1 AUDIO 1 Select CAM 14 CAM 1 AUDIO 2 Select CAM 14 CAM 1 AUDIO 2 Source CAM 14 CAM 1 AUDIO 3 Source CAM 14 CAM 1 AUDIO 3 Level CAM 14 CAM 1 AUDIO 4 Level CAM 14 CAM 1 AUDIO 4 TIMECODE TIMECODE Page 1 Page 1 Preset Status Level Dest X ...

Страница 70: ...LCD brightness values or you can view panel data The LCD button text varies with context in menu mode See Menu Mode on page 70 for more detail Name Set Toggle An Name Set Toggle button toggles the panel between its default name set and the system name set Whichever name set you select becomes the active name set S Name Set Toggle buttons are disabled while a category selection is in progress S The...

Страница 71: ... other navigation buttons Global navigate buttons however can access only static button pages They do not access list pages That is because configurers have no list options for global navigate buttons Page Down This button scrolls a list of levels in X Y mode or a list of MD devices in MD mode There are 3 options for scrolling 1 Scrolling the display only The items on the selection buttons do not ...

Страница 72: ...es locks and protects from preset source devices If source locks and protects are not used in your system this button is not needed If you select a source and someone else has locked or protected the source your panel will illu minate the Preset Release button and tell you who locked or protected the source You can release it if your panel has forced release enabled Note that you cannot lock or pr...

Страница 73: ...a take The default button text is Save Preset but the button can have any legend Selection Buttons Selection buttons correspond to the 8 lines of the alphanumeric display A selection button selects or deselects what appears on a line of the display In X Y mode the display shows levels and selection buttons select or deselect levels In MD mode the display shows MD destinations and the selection but...

Страница 74: ...il your presets are complete 4 Press Take The selected MD devices remain selected If you have not enabled Hold mode 1 Select an MD device Scroll the MD device display as needed 2 Select a source 3 Repeat steps 1 and 2 until your presets are complete 4 Press Take The selected MD devices become unselected The configurer can allow you to redefine certain MD destinations To do so is simple 1 select an...

Страница 75: ...e is Master button turns off the Broadcast button and vice versa The default button text is Source Master but the button can have any legend Take In X Y mode a take button routes the preset source device s on selected levels to the selected destination device In MD mode a take button switches the preset source device s to the selected destination device s on all levels The default button text is T...

Страница 76: ... The alphanumeric display also reflects the current mode Lock Protect and Release In a multi user system routes made by one user can be made safe from being accidentally or maliciously change by another user Definitions Owner The user ID of a panel where a lock or protect was issued Source lock No one can use the source Source protect No one but the owner can use the source Destination lock No one...

Страница 77: ...ny MD destinations at once Subse quently selecting a source assigns the source to all selected MD destinations You can turn Hold on and off as you require during an MD take Name Sets NV9000 SE Utilities allows configurers to define multiple name sets Each name set contains alternate device names for any and all devices in the NV9000 system The alternate device names can appear in the displays of y...

Страница 78: ...es requires that you perform a broadcast operation using a Broadcast button During broadcast the source device controls one or more destination devices Making Broadcast Routes Follow these steps to broadcast control signals 1 Ensure that the panel is in source is master mode It is either in source is master mode by default or you must press a Source is Master button to activate the mode The mode i...

Страница 79: ... of the display reads FREE for the machine control level in X Y mode If your panel is in multi destination mode you might switch to X Y mode momentarily to see this When a take involving a machine control level is blocked on the control level the display displays the message Control In Use If neither of the control ports for the source or destination are in use the take occurs naturally without an...

Страница 80: ...ss the chop button again to turn it off 2 select the destination you had chosen for the chop then 3 select any source Salvo Mode The NV9640A enters a minor salvo mode 1 when you press a salvo button Salvo mode is a temporary mode usually brief where you are given an opportunity to reconsider the salvo you are about to execute The NV9640A s display tells you the name of the salvo and instructs you ...

Страница 81: ...ress the User button to view user data The 2 buttons on the left tell you the user name and user ID as determined by the router control system These are not the Windows user name or ID S User names are important in lock protect and release situations The user who owns a lock or protect is identified by a user name Press Exit on the right to return to the menu Preset Status Level Dest Main Menu Sof...

Страница 82: ...le If you make a change press Save to commit the change or press Cancel to discard the change If you have made no changes just press Exit to return to the menu Panel ID Panel ID 6402 6402 PANEL PANEL NAME NAME D6402 D6402 IP ADDR IP ADDR 192 168 192 168 2 43 2 43 SVR_NAME SVR_NAME NVCONFIG NVCONFIG CFG FILE CFG FILE Z6402 Z6402 EXIT EXIT LCD HI LCD HI GREEN GREEN HIGH HIGH LCD LO LCD LO AMBER AMBE...

Страница 83: ...ess is a status message during initialization Until you connect the panel to its network the status message will remain the same Press the Menu button at the far right to access the setup menu There are 3 setup menu choices The Exit button at the far right allows you to leave the menu Panel ID Entry Press the Panel ID Entry button to set the panel ID A numeric button array appears Use the numeric ...

Страница 84: ...hen you do the button number appears under Button Num ber on button 1 and the button you pressed blinks rapidly on and off for about a half sec ond The up and down buttons are buttons 17 and 18 respectively and you can test these buttons the same way When you have finished testing buttons press Exit to return to the setup menu The panel test shows you 1 whether all the buttons are working and how ...

Страница 85: ...router control system can trigger events that through the relays in the NV9640A switch your tally devices The DB25 connector labeled GPI Interface at the rear of the NV9640A presents the tally signals There are 8 input signals and 4 pairs of output signals Fig 6 1 GPI Interface Input The tally inputs expect contact closure to ground through the ground pins on the connector to trigger a GPI input e...

Страница 86: ...witches the customer s circuit on or off It does not power the circuit Customers must provide their own power GPIO Configuration Concepts These are the I O characteristics of the NV9640A s tally interface Eight optically isolated inputs sometimes called GPIs that can be configured to trigger an event when the input transitions from off to on and to trigger another event on a transition from on to ...

Страница 87: ...port status and GPI input status When the conditions of the Boolean expression are met i e the expression is true the relay closes When the conditions are not met the relay opens Figure 6 4 shows one such Boolean expression Boolean expressions comprise terms and operators The operators include those indicated on the left AND OR and NOT Expressions can be parenthesized to control the order of evalu...

Страница 88: ... CTRL for output port status produces the sub expression CTRL on VTR3 has status of Used as broadcast slave which you can combine with other sub expressions as you require The actual logic takes place in the router control system based on the state of the NV9640A inputs and other system wide events The router control system sends signals to the NV9640A instructing it to open or close its relays Fo...

Страница 89: ...h event or both 1 Execute a salvo If you choose this behavior select a salvo ID in the salvo drop down list Note Although it is not evident in the GPIO input dialog or anywhere else a Previous Source command in a salvo chooses the most recent source that is different from the current source for a designated destination 2 Route the previous source that was switched by any control panel to a destina...

Страница 90: ...evices based on 1 NV9640A input transitions and 2 events in the router control system Its 8 inputs can be switched on or off by your external devices When an input transitions on or off the NV9640A can respond with one of 4 actions such as executing a salvo It is the system that actually executes the salvo ...

Страница 91: ...upply is an Miranda PS0001 00 Specification Detail DC power External power supply 12VDC 10 5A Power consumption 11W maximum 6W nominal Regulatory UL listed and CE compliant Specification Detail AC power 90 264 VAC 127 300VDC 47 447Hz Inrush current 50A at 230VAC cold start at 25 C Input current 2 0A rms at 115VAC 1 0A at 230VAC DC power 60W 12VDC 5A 5 4A peak Regulation 2 Ripple 120mV Efficiency E...

Страница 92: ...ut Specification Detail Dimensions Height 3 47 in 88 1mm fits EIA 2 RU 3 5 in or 88 9mm Width 19 0 in 482 6mm Depth 2 02 0 01 in 51 3mm enclosure 2 61 in 66 3mm overall Power 11W max at 120 VAC 6 W nominal Weight 1 916kg 4 22lb Connectors Power 2 connectors Molex 4 pin keyed Ethernet 1 connector 10 100baseT RJ 45 jack RS 232 1 connector 9 pin D type for diagnostics and upgrades GPIO DB25 Tally Int...

Страница 93: ...away button is a navigation button that displays a page of selection buttons The default panel options are Panel mode Multi destination Release mode Normal Default destination None Preset Monitor None Status Monitor None XY Data Routing Automatic MD Data Routing Automatic Default name set System names Multidest Device Limit 8 This is the lowest value The upper limit is 512 Src Dst Immediate Take E...

Страница 94: ...is set up to respond to DHCP from the factory It is possible to assign the panel a fixed IP address using the Panel IP Configuration Utility Drawings The drawings on the following pages identify features and provide overall and critical dimensions ...

Страница 95: ...85 NV9640A User s Guide Fig 7 2 Front and Top Views of the NV9640A 19 0 482 6 3 47 88 1 Alphanumeric display Function buttons 30 2 61 66 3 2 02 51 3 ...

Страница 96: ...86 Technical Details Drawings Fig 7 3 Rear and Top Views of the NV9640A 19 0 482 6 3 47 88 1 Ethernet Configuration RS 232 Power GPI and alarm ports 2 61 66 3 2 02 51 3 ...

Страница 97: ...87 NV9640A User s Guide ...

Страница 98: ...88 Technical Details Drawings ...

Страница 99: ...cannot represent these colors nor can a black and white printer Each color is represented in Figure 8 1 as a high tally low tally pair The colors of the up and down buttons are fixed When they are off they are white When they are on they are said to be amber This amber is not the same as for the LCD buttons it is pale and almost yellow The buttons are 24 5mm 23 5mm with the LCD portion about 20mm ...

Страница 100: ...90 Misc Topics Ordering Information ...

Страница 101: ...itching devices A level set also defines the mapping of each virtual level within the level set to a single physical level All levels in a level set have a unique display index within that level set Multi Desti nation Mode A mode on an NV9000 control panel that presents many destinations at once in contrast to X Y mode An operator may route sources to multiple destinations in a single take Multi d...

Страница 102: ...llow the system administrator to define a single physical router level as multiple levels Within a physical level any port can be mapped to any virtual level For example an AES matrix could be divided into AES 1 2 and AES 3 4 virtual levels X Y mode A mode on a control NV9000 control panel that switches one destination at a time in contrast to multi destination mode In X Y mode some panels can dis...

Страница 103: ...broadcast 25 54 65 68 cancel 72 73 category 24 26 49 54 55 chop 26 55 70 clear preset 4 18 26 43 56 default state 26 56 destination 26 49 54 56 destination lock 22 26 56 66 destination protect 22 26 57 66 edit panel configuration 15 exit 71 finish 15 forward 4 5 27 32 33 51 54 56 58 61 free source 8 27 57 global navigate 27 54 61 hold 7 22 27 58 information 27 60 LCD control 72 level map 27 49 58 ...

Страница 104: ...box 21 25 options 21 China contact 101 Choices navigation button 32 Chop 70 Chop button 26 55 70 Clear preset button 4 18 26 43 56 Color button 4 18 24 48 49 55 89 Commitment buttons 18 Configuration 2 button types for 25 NV9640A 13 of selection buttons 37 options 14 page 16 page default 16 83 pane 14 tasks 17 Connectors DB25 3 6 35 75 Ethernet 10 GPIO 3 6 35 75 power 10 RJ 45 10 RS 232 82 tally 3...

Страница 105: ...k 22 destination protect 22 force release 22 Environmental specifications NV9640A 83 ESD 9 Ethernet cable 10 11 Ethernet connector 10 Europe contact 101 European broadcasting union EBU 91 Examples symbol for 2 Exit button 71 Expressions Boolean 77 F FAX number 101 FCC statement ii Figures NV9640A front view 85 NV9640A front photo 3 NV9640A rear view 86 NV9640A rear photo 3 NV9640A top view 85 86 F...

Страница 106: ... option 32 Jump to multi dest selection when switching to XY option 22 L Last page Acrobat 2 LCD brightness 4 27 60 83 LCD buttons 4 12 17 18 27 LCD control button 72 Legends button 48 50 55 56 64 Level 27 breakaway 27 52 mapping 49 50 60 physical 91 92 sets 91 virtual 47 49 51 58 67 91 92 Level map button 27 49 58 Level mapping 8 Level set 51 Level Dest column 5 Levels 51 53 License agreement iii...

Страница 107: ...9 14 16 17 31 user s guide 2 NV915 system controller 2 NV920 system controller 2 NV960 system controller 2 NV9640A 9 10 13 89 configuration 13 front view 85 initialization 11 installation 9 rear view 86 top view 85 86 NV9642 2 NV96xx control panels 9 91 O Office hours 101 Operating temperature 83 Operator 91 Operators Boolean 77 Option page VFD only 30 Options checkbox 21 configuration 14 default ...

Страница 108: ...4 Relay outputs 3 6 75 76 Relay rule dialog 77 Release 8 66 forced 19 22 56 62 66 91 mode 19 22 83 normal 19 Restrictions iii Revert to saved button 16 18 Revision document ii RJ 45 connector 10 RoHS iii Router control system 2 RS 232 connector 82 Rules relay 77 S Safeguards iii Safety notices iii Salvo lists 47 61 mode 7 8 48 Salvo button 29 49 63 Salvo defined 91 Salvo mode 70 Salvos system 8 33...

Страница 109: ...82 83 low 2 outputs 13 75 76 83 Technical support 101 Temperature operating 83 Templates 8 15 40 44 55 Terms Boolean 77 Terms conventions and abbreviations 2 Testing your installation 12 Text button 18 Tielines 57 Trademarks iii Tree window 34 Tree button 4 Tree structured button layout 4 17 47 U Undefined button 17 30 65 UniConfig 9 United Kingdom contact 101 Use auto fill to create a new button ...

Страница 110: ...100 Index ...

Страница 111: ...0 a m 9 00 p m EST Telephone 1 800 224 7882 Fax 1 514 335 1614 E mail techsupp miranda com Europe Middle East Africa UK Office hours 9 00 a m 6 00 p m GMT Telephone 44 118 952 3444 Fax 44 118 952 3401 E mail eurotech miranda com France Office hours 9 00 a m 5 00 p m GMT 1 Telephone 33 1 55 86 87 88 Fax 33 1 55 86 00 29 E mail eurotech miranda com Asia Office hours 9 00 a m 5 00 p m GMT 8 Telephone...

Страница 112: ......

Отзывы: