34
Release Notes
Known Issues and Limitations
•
[Ref. #18331/18028]
If one or more cards in a Kaleido-X frame is being upgraded (i.e., if a
Live Update is in progress), then it is not possible to apply any changes made in
XAdmin. If you click the
Apply settings
link in the XAdmin sidebar, an error message
will appear. This restriction also occurs during the first 10 to 20 seconds after a card is
inserted into or removed from the frame.
Workaround:
Wait until the upgrade has finished, then click
Apply settings
again.
•
[Ref. #17602]
Kaleido-X expansion systems:
XAdmin always reports a normal status for
“KXO-EXP - Link: Cable crossed”, in the
Status and options
page, regardless of whether
the expansion cables are physically crossed or not.
XEdit
[Ref. #KX-4901]
Saving layout changes:
Saving a layout may fail, when the zoom factor
XEdit uses to display it is higher than 50%.
Workaround:
Zoom out (e.g. all the way down to 2%) before saving your changes.
[Ref. #KX-6243]
Copy properties tool:
The Copy properties tool may fail to copy UMD
blink mode settings from one monitor to another in a layout, resulting in UMD behavior
that does not match your expectations on the monitor wall. This typically only occurs
when the first text level is selected as the text label level assignment.
Workaround:
Remove any affected monitors from the layout, and then add them again,
this time configuring their properties manually.
[Ref. #KX-6261]
Global alarms:
In the sources table, the ability to include or exclude a
level's contribution to the global alarms is only relevant for alarm levels although the
properties are also available for other levels such as text and time code.
•
[Ref. #35436]
Logical source names:
If your configuration includes logical sources with
names based on router source labels that are set locally in XEdit (i.e. in the
Source/Destination mapping configuration for the corresponding router, you cleared
the option
Get labels from physical level
, and either typed the labels manually or
imported them from a CSV file), then further changes to these router source labels in
the router configuration are not reflected in the sources table (under
Source info
).
Workaround:
In the sources table, right-click the name you wish to refresh, click
Copy
assignment
on the menu, right-click again, and then click
Paste assignment
.
•
[Ref. #25781]
Incorrect multi-viewer model:
On rare occasions, if you use XEdit with
different models of multi-viewer, you may notice that the model indicated in a system
configuration does not match the actual multi-viewer anymore, and that the system’s
logical sources have assignments marked in red.
Workaround:
If you have a recent backup of your system configuration, restore this
backup to your local workspace, and then export it to the multi-viewer. Alternatively,
right-click the multi-viewer in the System list, click the “replace with...” option that
matches your actual multi-viewer model, and then make sure to reply
No
when XEdit
prompts you to confirm whether you want to restore the database factory defaults.
•
[Ref. #28263]
Java 6:
If you try to open XEdit from a PC or laptop that does not have Java
6 update 20, Java Web Start may automatically download the JRE installer (instead of
first showing a Web page prompting you to do it), in which case, for some users, the
download eventually fails and an error message appears: “Unable to download”.
Workaround:
Download Java 6 update 20 manually by clicking the link at the bottom of
the Kaleido-X home page, and then install it.