6
Release Notes
Bug Fixes
•
[Ref. F33725/F26951]
Text rendering on monitor wall:
Improved readability of text
elements on UMDs, clocks, audio level meters, time code monitors, timers, and XDS
metadata monitors. The improvements are most noticeable on monitor wall displays
associated with a KMV-3901/3911 multi-viewer.
•
[Ref. #26263]
Text rendering of CC/subtitling on monitor wall:
Support for displaying
CC/subtitling in a larger font size.
Bug Fixes
Bugs Fixed in Kaleido-X Version 6.51
[Ref. #37117/37260]
Kaleido-IP:
In some circumstances, XEdit may become unresponsive
when connected to a Kaleido-IP multiviewer.
[Ref. #KX-6211]
Kaleido-IP:
The Kaleido-IP may fail to distinguish between multiple
instances of a program when the same multicast stream is added to different network
adapters.
[Ref. #KX-6276]
Kaleido-IP:
At startup, a Kaleido-IP system with audio monitoring enabled
may fail to show some of the programs assigned to monitors in the current monitor
wall layout: a number of video windows may remain blank, and some audio monitors
could be unresponsive. In addition, some alarms may appear with a disabled status in
XEdit.
[Ref. #KX-6284]
Virtual alarms:
XEdit version 6.50 does not allow building virtual alarms
associated with an iControl Application Server that has iControl version 4.30 (or later).
Bugs Fixed in Kaleido-X Version 6.50
•
[Ref. #36705]
Router control:
In the case of a multi-viewer configured to control an
upstream router, if the router configuration includes a
logical level ID
that was changed
at some point for something other than the default value (0) then further modifications
to the router configuration in XEdit may momentarily disable your multi-viewer’s router
control features, until you restart the multi-viewer.
•
[Ref. #36828]
Clusters:
In the case of a cluster where members are configured with
upstream routers sharing the same friendly name, restarting a cluster member may
result in some monitors failing to reflect further crosspoint changes, on the monitor
wall.
•
[Ref. #36403]
Virtual alarms:
Since version 6.30 of the Kaleido-X software, when you
attempt to edit a virtual alarm, any global alarms that were contributing to this virtual
alarm may disappear from the virtual alarm definition, if they were generated from
Note:
As a result of this change in the URI/path structure, it is now
necessary to reassign any virtual alarms that were created on a multi-viewer
before the change, and used in iControl Web pages. Virtual alarms created in
iControl are not affected.
Note:
This feature applies to the Kaleido-X and Kaleido-X16 multi-viewer
models only, and is in a beta stage.