6 Starting operation
6.8 Identification & maintenance
functions (I&M)
6.8.1 Supported I&M features
Module-specific I&M features
The module-specific I&M features 0 through 4 can be read or written via slot
0. The specified index is used for mapping the data sets.
Data object
Length
[byte]
Access Default value / Description
MANUFACTURER_ID
2
Read
0x016A (Belden Deutschland GmbH)
ORDER_ID
20
Read
Order number of module in ASCII
SERIAL_NUMBER
16
Read
Defined in production process in ASCII
HARDWARE_REVISION
2
Read
Hardware revision of device
SOFTWARE_REVISION
4
Read
Software revision of device
REVISION_COUNTER
2
Read
Incremented for every statically stored
parameter change on IOLink Master (e.g.,
device name or IP address)
PROFILE_ID
2
Read
0xF600 (Generic device)
PROFILE_SPECIFIC_TYPE
2
Read
0x0003 (IO modules)
IM_VERSION
2
Read
0x0101 (I&M Version 1.1)
IM_SUPPORTED
2
Read
0x001E (I&M 1 … 4 is supported)
Table 8: I&M 0 (Slot 0, Index 0xAFF0)
Data object
Length
[byte]
Access Default value / Description
TAG_FUNCTION
32
Read/
Write
0x20 ff. (empty)
TAG_LOCATION
22
Read/
Write
0x20 ff. (empty)
Table 9: I&M 1 (Slot 0, Index 0xAFF1)
Manual LioN-P PROFINET IO-Link Master
Version 2.1 10/2017
59