Protocol settings for
Digital I/O modules
10
4.2 Factory reset
Information sheet LioN-P multiprotocol
Release 1.2 04/2017
4.1.2
PROFINET
If you decide to use PROFINET, set the first rotary encoding switch to the
value of P. For more Information use the LioN-P PROFINET Digital I/O
manual.
4.1.3
EtherCAT
If you decide to use EtherCAT, set the first rotary encoding switch to the
value of EC. For more information use the LioN-P EtherCAT Digital I/O
manual.
4.2
Factory reset
A factory reset restores the original factory settings and thus resets the
changes and settings you have made up to that point. It also resets the
protocol selection. To perform a factory reset, set the first rotary encoding
switch (x100) to 9, the second (x10) to 7, and the third (x1) also to 9.
Afterwards perform a power cycle and wait 10 seconds.
Follow the steps from section
“EtherNet/IP – PROFINET – EtherCAT” on
again to select a new protocol.
x100
x10
x1
Factory Reset
9
7
9