9 Diagnostics processing
9.6 Diagnostic history object (0x10F3)
code 0x06090030 (value range of
parameter exceeded) in the following
case: SI3 is written with a value of
a sub-index which does not hold a
message.
Writing = 69...255:
The slave returns SDO abort
with code 0x06090031 (value of
parameter written too high).
9.6.4 New Messages Available
Overwrite mode:
0: newest message was read
1: newest message was not read
Acknowledge mode:
0: no unacknowledged message
1: diagnosis messages are available which can be acknowledged (SI2 != SI3).
9.6.5 Flags
Flags to control sending and storing of diagnosis messages:
Bit 0: Enable Emergency sending
0: Default, if device does not support emergency
sending.
1: New diagnosis messages shall be sent as emergency
message.
Bit 1: Disable info messages
0: Info messages are stored in the diagnosis message
queue (default).
1: Info messages will not be stored in the diagnosis
message queue.
Bit 2: Disable warning messages
Manual EtherCAT®
Version 1.1 04/2021
85