Installation RSP20/25/30/35
Release 18 09/2021
41
2.5.2
Supply voltage with the characteristic value KK
You will find information on the characteristic values here:
“Device name and product code” on page 24
You have the option of supplying the supply voltage redundantly, without
load distribution.
Both supply voltage inputs are uncoupled.
With a redundant supply, the supply voltage 1 (upper voltage input on the
device) has priority.
Figure 5: Supply voltage with the characteristic value KK: 3-pin terminal block with
screw locking
Type of the voltages
that can be
connected
Specification of the supply
voltage
Pin assignment
DC voltage
Rated voltage range DC:
60 V DC ... 250 V DC
Voltage range DC incl.
maximum tolerances:
48 V DC ... 320 V DC
+/L
Plus terminal of the supply voltage
-/N
Minus terminal of the supply
voltage
Protective conductor
AC voltage
Rated voltage range AC:
110 V AC ... 230 V AC,
50 Hz ... 60 Hz
Voltage range AC incl.
maximum tolerances:
88 V AC ... 265 V AC,
47 Hz ... 63 Hz
+/L
Outer conductor
-/N
Neutral conductor
Protective conductor
Table 8:
Supply voltage with characteristic value KK: type and specification of the
supply voltage, pin assignment
WARNING
ELECTRIC SHOCK
Install this device only in a switch cabinet or in an operating site with
restricted access, to which maintenance staff have exclusive access.
Failure to follow this instruction can result in death, serious injury, or
equipment damage.
N
L