Installation RS20/22/30/32/40
Release 07 10/2021
59
3
Making basic settings
The IP parameters must be entered when the device is installed for the first
time. The device provides the following options for configuring IP addresses:
Configuration via V.24 connection
Configuration using the HiDiscovery protocol
Configuration via BOOTP
Configuration via DHCP
Configuration via DHCP (Option 82)
Configuration using AutoConfiguration Adapter
3.1
Applies to devices with a software version
before HiOS 7.1/8.1
3.1.1
Default settings
IP address: The device looks for the IP address using DHCP
Password for management:
Login: user; password: public (read only)
Login: admin; password: private (read and write)
V.24 data rate: 9600 Baud
Ring redundancy: disabled
Ethernet ports: link status is not evaluated (signal contact)
Optical 100 Mbit/s ports: 100 Mbit/s full duplex
All other ports: autonegotiation
Redundancy Manager disabled (DIP switch RM and Stand-by: ON)
Stand-by coupling disabled (DIP switch RM and stand-by: ON), Port 4 =
control port, Port 3 = coupling port for redundant ring coupling
Rapid Spanning Tree enabled
WARNING
UNINTENTIONAL OPERATION IN DEVICE
Install and maintain a process that assigns a unique IP address to every
device in the network.
Failure to follow this instruction can result in death, serious injury, or
equipment damage.