background image

 
 
 
 
 

qSCALE  
maestro

 

 

 PLC v01.00.00

 

  

Contents 

 

Safety instructions 

Product description 

Operating Mode Selection 

Operation 

Service and Maintenance 

Appendix 

Operators Manual 

 
 

Issue H – 01/2018 

HMI v01.00.00 

This document has the order number: 

MAN-QSCA-O-0007 

Содержание Hirschmann qSCALE D2 maestro

Страница 1: ...Contents Safety instructions 1 Product description 2 Operating Mode Selection 3 Operation 4 Service and Maintenance 5 Appendix 6 Operators Manual Issue H 01 2018 HMI v01 00 00 This document has the o...

Страница 2: ...eration Mode 13 4 Operation 16 4 1 Main Working Screen 17 4 1 1 Warning Lights Audible Alarm 18 4 2 Work Area Limitations 19 4 2 1 Height Monitoring 21 4 2 2 Radius Monitoring 22 4 2 3 Boom Angle Moni...

Страница 3: ...Codes Table 44 VERSION OVERVIEW Issue Date Description Editor A 10 2017 Initial Release HMI v01 00 00 RBM B 11 2017 Replaced Cover Image and added references to vSCALE D2 Console RBM C 11 2017 Added e...

Страница 4: ...duplicated repro duced or translated into another language either wholly or partly without the prior written permission of Hirschmann Automation and Control GmbH The rendition of common names trade n...

Страница 5: ...manual WARNING Warning of direct threat of personal injury and damage to property Instructions on precautions to avert the danger CAUTION Warning of dangerous situations Also warns of damage to prope...

Страница 6: ...ring the SETUP procedure The settings can only be carried out by operators who are completely familiar with the operation and functions of the machine and the RCL The correctness of these settings mus...

Страница 7: ...S6 maestro central control unit vSCALE D2 D3 maestro console various sensors for detection of machine status and environmental conditions The vSCALE D2 D3 maestro console is used for programming and...

Страница 8: ...00 00 Operators Manual Issue H HMI v1 0 0 01 2018 rbm 2 1 Product Identification The type plate carries the unique identification of the operating console It is located on the back of the device Pleas...

Страница 9: ...ion and Confirmation SET key Selects Settings Silences Alarm HOME key Returns to Main Working Screen ESCAPE key Aborts Function Display with RCL Main Menu Rotary Encoder with Pushbutton Function For S...

Страница 10: ...v1 0 0 01 2018 rbm 2 3 Overview Feedback Elements Light Sensor Not Used Operating Display Green While Supply Voltage is Connected USB Data Display Yellow During Data Exchange via Front USB Port Wirele...

Страница 11: ...operating mode 3 1 Switching Device On and Off The load limiting device has no on off switch The console automatically switches on with PTO power After boot up the following appears on the display Ope...

Страница 12: ...or operation until all faults have been rectified and no error codes are displayed The error codes are displayed in red color The warning codes are displayed in yellow color When confirming the operat...

Страница 13: ...uring the SETUP procedure The settings can only be carried out by operators who are completely familiar with the opera tion and functions of the machine and the RCL The correctness of these settings m...

Страница 14: ...ct options Start SETUP Operating Mode Setup can be called from the main RCL operating menu by pressing the function key Select Reeving Selection Press the button to enter the Select Reeving Menu When...

Страница 15: ...knob or up and down arrows to select the operating mode that corresponds to the current machine setup Ensuring that the Jib and Outriggers match the description shown on the right Confirm Selections A...

Страница 16: ...familiar with all operating elements of the RCL before operating the machine All settings must be checked by hoisting a known load and comparing the information with that displayed by the RCL WARNING...

Страница 17: ...creen and can be set up in the Settings Menu Settings see Section 5 1 Set or Disable Tare see Section 4 3 Camera see Section 4 6 Set Operating Mode see Section 3 2 Work Area Limitations see Section 4...

Страница 18: ...e imminent Overload Error This red symbol is lit to indicate that an error has occurred such as the maximum machine load has been reached or exceeded The audible alarm sounds an uninterrupted tone RCL...

Страница 19: ...See Section 4 2 2 Boom Angle Monitoring See Section 4 2 3 Wind Speed Monitoring See Section 4 2 4 Programming is carried out via an interactive menu The functions can be set individually or in combina...

Страница 20: ...ues are exceeded Angle Limit see Section 4 2 3 Wind Speed Limit see Section 4 2 4 Radius Limit see Section 4 2 2 Deactivate all Limits Height Monitoring see Section 4 2 1 The colors of the function bu...

Страница 21: ...m 21 53 qSCALE maestro PLC v01 00 00 Operators Manual Issue H HMI v1 0 0 01 2018 rbm 4 2 1 Height Monitoring Boom Height Limit is able to be programmed HOME LIMITS HEIGHT Save Current Boom Head Height...

Страница 22: ...rbm 4 2 2 Radius Monitoring Upper and Lower Radius Limits are able to be programmed HOME LIMITS RADIUS Save Current Radius as Maximum Radius Limit Save Current Radius as Minimum Radius Limit Turn On...

Страница 23: ...m 4 2 3 Boom Angle Monitoring Upper and Lower Boom Angle Limits are able to be programmed HOME LIMITS BOOM ANGLE Save Current Radius as Maximum Angle Limit Save Current Radius as Minimum Angle Limit T...

Страница 24: ...C v01 00 00 Operators Manual Issue H HMI v1 0 0 01 2018 rbm 4 2 4 Wind Speed Monitoring Maximum safe operating Wind Speed can be programmed HOME LIMITS WIND SPEED Sets Upper Wind Speed Limit see instr...

Страница 25: ...rotary knob to select the numbers Pressing the knob to move to the next digit 3 Press the button to add a decimal point 4 Use the button to change the input be tween a negative or positive value 5 Use...

Страница 26: ...ratus The tare is removed when the operating mode changes the length or angle of the boom changes or pressed NOTE The current load includes the weight of the load block the lifting rope and all load s...

Страница 27: ...ay the Error Event function button Pressing the Error Event function button will bring up the Error Event Page which displays error spe cific information If the Alarm is already muted the Silence butt...

Страница 28: ...tions com 28 53 qSCALE maestro PLC v01 00 00 Operators Manual Issue H HMI v1 0 0 01 2018 rbm 4 6 Camera If an external camera in installed it can be viewed from the console by pressing the button Rota...

Страница 29: ...ue H HMI v1 0 0 01 2018 rbm 5 Service and Maintenance 5 1 Settings Menu System settings can be found under the Settings Menu HOME SETTINGS Sensor Calibration See Section 5 4 Machine Information Screen...

Страница 30: ...v1 0 0 01 2018 rbm 5 2 Machine Information The Machine Information Screen shows the Machine Model Machine Serial Number as well as Digital Outputs Analog Inputs and Digital Inputs HOME SETTINGS MACHIN...

Страница 31: ...al Issue H HMI v1 0 0 01 2018 rbm 5 2 2 Status of Digital Outputs The system Digital Output Information is displayed here See the Service Manual for more detail HOME SETTINGS MACHINE INFO DIGITAL OUTP...

Страница 32: ...Operators Manual Issue H HMI v1 0 0 01 2018 rbm 5 2 3 Status of Digital Inputs The system Digital Input Information is displayed here See the Service Manual for more detail HOME SETTINGS MACHINE INFO...

Страница 33: ...v01 00 00 Operators Manual Issue H HMI v1 0 0 01 2018 rbm 5 2 4 Readings of Analog Sensors Readings of the analog sensors can be called up See the Service Manual for more Detail HOME SETTINGS MACHINE...

Страница 34: ...00 00 Operators Manual Issue H HMI v1 0 0 01 2018 rbm 5 3 User Screen Alarm volume display brightness key brightness and measurement units can be selected in the User Screen HOME SETTINGS USER SCREEN...

Страница 35: ...densolutions com 35 53 qSCALE maestro PLC v01 00 00 Operators Manual Issue H HMI v1 0 0 01 2018 rbm 5 3 1 LCD Brightness The LCD Screen brightness can be adjusted in the User Screen HOME SETTINGS OUTP...

Страница 36: ...tions com 36 53 qSCALE maestro PLC v01 00 00 Operators Manual Issue H HMI v1 0 0 01 2018 rbm 5 3 2 Key Brightness The Brightness of the Keys on the console can be adjusted in the User Screen HOME SETT...

Страница 37: ...s com 37 53 qSCALE maestro PLC v01 00 00 Operators Manual Issue H HMI v1 0 0 01 2018 rbm 5 3 3 Unit Selection The measurement units can be switched between US and SI units HOME SETTINGS USER SCREEN UN...

Страница 38: ...Issue H HMI v1 0 0 01 2018 rbm 5 4 Sensor Calibration The sensors must be calibrated before operation after installation HOME SETTINGS SENSOR CALIBRATION Angle Sensor Calibration See Service Manual L...

Страница 39: ...System Information screen you can set the Date and Time view and reset the runtime of the system rotate the display download the event recorder data and download updates from the USB HOME SETTINGS SY...

Страница 40: ...ET function buttons simultaneously o A screen shot of the current screen will be saved 5 6 2 Saving Screen Captures If a USB drive is installed in the console the screen capture will be saved to the U...

Страница 41: ...Device may be damaged by the use of high pressure cleaners The device must not be treated with a high pressure cleaner or similarly aggressive method under any circumstances Condensation inside the qS...

Страница 42: ...up to 48V DC Display 4 3 TFT Color Graphic LCD 480 x 272 Pixel WVGA Or 7 TFT Color Graphic LCD 800 x 480 Pixel WVGA Brightness 400 cd m Contrast 400 1 or 500 1 Illumination LED adjustable brightness...

Страница 43: ...6 2 Password Entry Password entry is done by the following instructions Use the rotary knob to select the numbers pressing the knob to move to the next digit Use the or buttons to select the number in...

Страница 44: ...0xx General Error Other 2xxx Module Error 3xxx Module Error 1Fxx System 01xx Limiter Error Global Cut 02xx Single Cut 03xx Error 04xx Warning 05xx Pre Warning 0Axx Kinematic Error Kinematic 0Bxx Kinem...

Страница 45: ...012D Max length limit exceeded global cut Telescope into the permitted Working Range load chart E0140 Min radius limit underrun global cut Move the Jib down to a valid radius and angle E0141 Max radiu...

Страница 46: ...F E0A00 Capacity utilization 100 Lay down the load Only operate within allowed parameters E0A08 Capacity utilization 90 Warning Operating close to Cut off E0A20 Shutdown due to overload Lay down the l...

Страница 47: ...ce faulty sensor E1X1A Sensor Error IOInput3 Check the CAN connections and wiring the sensor calibration and the CAN configuration Replace faulty sensor E1X1B Sensor Error IOInput4 Check the CAN conne...

Страница 48: ...tuator Error IOCut Check the CAN connections and wiring the sensor calibration and the CAN configuration Replace faulty sensor E1X63 Actuator Error IORigging Check the CAN connections and wiring the s...

Страница 49: ...eout Turn the Ignition off and on again Consult Customer Service if the error occurs again E1F07 Timeout Turn the Ignition off and on again Consult Customer Service if the error occurs again E1F10 Com...

Страница 50: ...chmann Automation and Control GmbH Mobile Machine Control Solutions www beldensolutions com 50 53 qSCALE maestro PLC v01 00 00 Operators Manual Issue H HMI v1 0 0 01 2018 rbm This page intentionally l...

Страница 51: ...trouble free operation We take the task of continuous improvement and reduction of errors very seriously Your comments and suggestions help us to increase the quality and level of information for thi...

Страница 52: ...v1 0 0 01 2018 rbm Suggestions for improvement and additional information General comments Sender Company Department Name Phone Street Zip code City Date Signature Dear user please complete and retur...

Страница 53: ...2018 Hirschmann Automation and Control GmbH Mobile Machine Control Solutions www beldensolutions com 53 53 qSCALE maestro PLC v01 00 00 Operators Manual Issue H HMI v1 0 0 01 2018 rbm Notes...

Отзывы: