Installation MACH104-PoEP
Release 06 11/2013
21
The following table applies to all other ports:
1.8
Management interfaces
1.8.1
V.24 interface (external management)
The V.24 interface is an RJ11 socket.
The V.24 user interface is serial and allows you to connect the following
devices directly:
External management station (VT100 terminal or PC with appropriate
terminal emulation). With this management station, the Command Line
Interface (CLI) is available to you. Furthermore, the system monitor is
available to you at the system start.
An AutoConfiguration Adapter ACA 11
The socket housing is electrically connected to the front panel of the device.
The V.24 interface is not electrically isolated from the supply voltage.
Figure 2: Pin assignment of the V.24 interface and the DB9 connector
LED
Display
Color
Activity
Meaning
left LED Link status
None
The device detects an invalid or
missing connection.
Green
Lights up
The device detects a valid
connection.
Flashes 1 time a period The port is switched to stand-by.
Flashes 3 times a period The port is disabled.
Yellow
Flashing
The device is sending and/or
receiving data.
right LED
(if present)
permanently active
VT 100 terminal settings
Speed
9,600 Baud
Data
8 bit
Stopbit
1 bit
Handshake
off
Parity
none
1
1
8
5
6
2
3
5
1
2
3
4
5
6
CTS
n.c.
TX
GND
RX
RTS
RJ11
DB9
RJ11
DB9