Installation GRS105/GRS106
Release 01 11/2021
The supply voltage is electrically isolated from the casing. The power supply
units are protected against polarity reversal.
With a non-redundant supply of the supply voltage, the device reports the
loss of a supply voltage. You can prevent this message by applying the
supply voltage via both inputs, or by changing the configuration in the device
management.
5.4.1
Supply voltage characteristic value G
You have the option of supplying the supply voltage redundantly, with load
distribution.
The supply voltage is electrically isolated from the casing.
Note:
The supply voltage is connected to the device casing through
protective elements exclusively.
Figure 1: Supply voltage with characteristic value G: non-heating-appliance cable
connection with built-in C14 plug according to IEC 60320-1
5.4.2
Supply voltage characteristic value M
You will find information on the characteristic values here:
“Device name and product code” on page 21
You have the option of supplying the supply voltage redundantly, with load
distribution.
Both supply voltage inputs are electrically isolated.
Type of the voltages
that can be connected
Specification of the supply
voltage
Pin assignment
AC voltage
Rated voltage range
110 V AC ... 240 V AC,
50 Hz ... 60 Hz
L
N
Line conductor
Neutral conductor
Protective conductor
Table 9:
Type and specification of the supply voltage, connections