32
Installation BAT867-R
Release 10 09/2021
Figure 1: Supply voltage with characteristic value U: 2-pin terminal block with screw
lock
Proceed as follows:
Verify the required conditions for connecting the voltage supply.
See “Requirements for connecting electrical wires” on page 10.
See “Requirements for connecting the supply voltage” on page 11.
Remove the terminal connector from the device.
Connect the protective conductor with the clamp.
Connect the wires according to the pin assignment on the device with the
clamps.
2.5
Operating the device
Type of the voltages
that can be
connected
Specification of the supply
voltage
Pin assignment on the device
DC voltage
Rated voltage
24 V DC
Voltage range incl. maximum
tolerances
18 V DC ... 32 V DC
−
Minus terminal of the supply
voltage
+
Plus terminal of the supply voltage
Table 4:
Supply voltage with characteristic value U: type and specification of the
supply voltage, pin assignment on the device
WARNING
ELECTRIC SHOCK
Before connecting the electrical wires,
always
verify that the requirements
listed are complied with.
See “Requirements for connecting electrical wires” on page 10.
See “Requirements for connecting the supply voltage” on page 11.
Failure to follow this instruction can result in death, serious injury, or
equipment damage.
−
+
Содержание Hirschmann BAT867-R
Страница 57: ...Installation BAT867 R Release 10 09 2021 57...
Страница 58: ......