Video Processor Frame Traps
Table 24. Supported K-Frame SNMP Traps
Name
Type
Description
Severity
vsmPowerSupplyStatusChange
status
If the current status is different than the last
status then a trap is sent. A power supply OK
message is only sent if all power supplies are
OK after one of more power supplies have
failed or been removed. At boot time, the first
running status generates an informational
message. After that, a transition to the running
status generates a normal message.
comm error = alarm
fault = alarm
power supply removed = warning
power supply OK = normal
vsmFanStatusChange
status
If the fan board is not present or if all fans have
stopped working a trap is sent. This trap is
resent every 12 seconds until the condition is
corrected.
If any of the fans are not working properly a
trap is sent. This trap is resent every 20 sec-
onds until the condition is corrected.
When the system starts running normally or
returns from an abnormal condition to running
normally a trap is sent.
fan board not present = alarm
all fans not working = alarm
fan not working = warning
normal operation = informational (start up),
normal (returning from a warning or alarm condition)
vsmTempStatusChange
status
If temperature crosses the warm threshold in
any direction a trap is sent.
hot = alarm
normal = normal
vsmModuleStatusChange
powerOK
If the current power status is different than the
last power status a trap is sent.
power OK = normal
power Fault = alarm
vsmModuleStatusChange
status
If the current status is different than the last
status a trap is sent.
operational = normal
failed = alarm
not inserted = warning
vsmReferenceStatusChange
status
When the video reference transitions between
locked and not locked in either direction a trap
is sent.
not locked = warning
locked = normal
gvgElStateChange
status
When the switcher starts the boot process and
the trap status is “initializing” a trap is sent.
Another trap is sent when the switcher
becomes fully operational and the trap status
is “running”.
initializing = warning
running = normal
Содержание Grass Valley Kayenne K-Frame
Страница 2: ......
Страница 30: ...30 KAYENNE K FRAME Installation Service Manual Regulatory Notices ...
Страница 42: ...42 KAYENNE K FRAME Installation Service Manual Section 1 Introduction ...
Страница 108: ...108 KAYENNE K FRAME Installation Service Manual Section 4 System Cabling ...
Страница 175: ...KAYENNE K FRAME Installation Service Manual 175 Configuration File Save and Load Figure 121 Files Ops User Setups Menu ...
Страница 186: ...186 KAYENNE K FRAME Installation Service Manual Section 5 Basic Configuration Figure 126 PGM Output Assigned to Suite 2 ...
Страница 208: ...208 KAYENNE K FRAME Installation Service Manual Section 5 Basic Configuration ...
Страница 270: ...270 KAYENNE K FRAME Installation Service Manual Maintenance ...