Multiple Suite Resource Sharing
Independent Resource Sharing
Independent resource sharing isolates an operator or group of operators
from other operators, by defining two separate suites. When one suite has
acquired a resource, only the operator or group of operators in that suite
will be able to control it. An example of independent sharing is splitting a
4-ME Kayenne K-Frame system into two independent 2-ME switchers.
When a suite acquires a physical resource (like an ME) it uses that resource
logically. For example, the ME B physical resource can be used as a logical
PGM PST bank. Each of the two switchers created can therefore have their
own PGM PST bank, and this allows effects built in one suite to operate cor-
rectly when loaded and run in the other suite. Effects will also run correctly
in the same suite when run at a later time even if different physical
resources have been acquired. Resources can be released by a suite. Once
released, these resources can be acquired by the other suite. This permits
dynamic reconfiguration of the system resources to meet varying opera-
tional requirements.
Suite
A suite is a grouping of one or more control surfaces (described below), and
constitutes a coordinated working environment. Resources are attached to
a suite rather than to individual control surfaces. All control surfaces in one
suite have access to all resources assigned to that suite (collaborative
sharing). Control surfaces in one suite are not able to control resources
assigned to the other suite (independent sharing). Suites provide isolation
from operators in the other suite.
Содержание Grass Valley Kayenne K-Frame
Страница 2: ......
Страница 30: ...30 KAYENNE K FRAME Installation Service Manual Regulatory Notices ...
Страница 42: ...42 KAYENNE K FRAME Installation Service Manual Section 1 Introduction ...
Страница 108: ...108 KAYENNE K FRAME Installation Service Manual Section 4 System Cabling ...
Страница 175: ...KAYENNE K FRAME Installation Service Manual 175 Configuration File Save and Load Figure 121 Files Ops User Setups Menu ...
Страница 186: ...186 KAYENNE K FRAME Installation Service Manual Section 5 Basic Configuration Figure 126 PGM Output Assigned to Suite 2 ...
Страница 208: ...208 KAYENNE K FRAME Installation Service Manual Section 5 Basic Configuration ...
Страница 270: ...270 KAYENNE K FRAME Installation Service Manual Maintenance ...