50
Frame Operation and IP Network Setup
Network Considerations for a Multiviewer Cluster
Between multiviewer and SNMP managers
Between multiviewer and NTP server
The following ports, used for communications to/from Network Time Protocol servers, are
open by default on all
Kaleido Multiviewer
systems:
Network Considerations for a Multiviewer Cluster
• If you change the system name or IP address of a cluster member while another cluster
member is offline or otherwise unavailable, the cluster’s integrity will be broken. If you
attempt to make such a change, XEdit will alert you of the situation, prompting you to
cancel the operation and try again later, when all cluster members are available.
However, in the advent that such a change was made by mistake, or that it as been
forced for some reason, you will have to repair the broken cluster (see “Repairing a
Cluster System” in the Kaleido Software User’s Manual
• To maintain the integrity of a cluster configuration, such changes must be made by
using the system configuration features available in XAdmin.
Port
Used for
Transport Notes
161
SNMP
UDP
Used for SNMP (Simple Network Management Protocol)
communications between external SNMP managers and a
multiviewer (e.g., sending get, get-next, and set messages
to a multiviewer’s SNMP agent, and receiving the response).
Port
Used for
Transport Notes
123
NTP
TCP
Used for Network Time Protocol synchronization. Port
needs to be open in both directions.
IMPORTANT
Before changing the system name or IP address of a multiviewer
associated with a cluster, review the following.
Содержание Grass Valley KALEIDO-X16
Страница 20: ...20 Overview Functional block diagrams...
Страница 26: ...26 Installation CompactFlash...
Страница 42: ...42 Multiviewer Cabling Enabling EDID Auto Detection from the Monitor Wall...
Страница 126: ...126 Configuring a Kaleido X16 Cascade Limitations...
Страница 151: ...151 Kaleido X16 Hardware Description Installation Manual...