IP Network Setup
TCP/UDP Port Usage
From iControl to multiviewer
Between multiviewer and remote control panel
The following ports, used for communications to/from RCP-200 and Kaleido-RCP2 control
panels, are open by default on all Kaleido Software systems:
7572
UDP
On multicast 230.8.8.8 for “keep-alive” (heartbeat)
7571
UDP
For “keep-alive” (heartbeat)
Port
Used for
Transport Notes
4160
Java Jini
TCP
Responsible for discovery and communications between
devices/services on a network.
32768–
65535
Java RMI TCP
Remote Method Invocation (client/server
communication). Dynamic Allocation of ports. Required
for communication between client and Application
Server. This range can be restricted to match specific
security requirements. A minimum of 4000 ports should
be allocated.
Port
Used for
Transport Notes
5120
RCP2
TCP
Used to listen for Kaleido Software discovery packets
10000
TCP
For RCP2 protocol
10001
TCP
For RCP2 protocol
5120
UDP
On multicast 230.8.8.9 for RCP2 protocol
5121
UDP
For RCP2 protocol
80
HTTP
TCP
Used by the RCP-200 to obtain information from the
multiviewer’s system database
13000
TCP
Used by the RCP-200 to control the multiviewer via the
gateway
Port
Used for
Transport Notes
Содержание GRASS VALLEY KALEIDO Series
Страница 14: ...14 Table of Contents...
Страница 17: ...17 Kaleido IP X320 X120 Installation Service Manual Overview of the Kaleido IP System...
Страница 18: ...18 Overview Overview of the Kaleido IP System...
Страница 22: ...22 Installation Setting up the Kaleido IP Hardware...
Страница 28: ...28 Multiviewer Cabling Changing the Output Resolution...
Страница 117: ...117 Kaleido IP X320 X120 Installation Service Manual For more information about recycling contact Grass Valley...
Страница 118: ...118 Maintenance Troubleshooting Disposal and Recycling Information...
Страница 127: ...127 Kaleido IP X320 X120 Installation Service Manual...