96
Installing the SFP Output Module
Connecting the fiber optic cables
3 Slide the module straight into the socket, and push gently until it clicks into position.
Connecting the fiber optic cables
1 Remove the dust plug from the SFP module if present
2 Verify that the exposed end of the optical fiber in the LC connector is clean
• Carefully remove any debris if necessary.
3 Plug the LC-terminated fiber optic cable into the SFP module
Removing the fiber optic cables
1 Grasp the LC fiber optic connector that is plugged into the SFP module, and pull it
straight out to disengage the optical fiber from the SFP.
• Never pull the fiber optic cable itself, as irreversible damage may occur.
2 Insert a dust plug into the SFP module.
Removing the SFP module
1 Move the bale clasp lever to the open position.