56
IPVU Commissioning and Configuration
Time Sync Configuration
Time Sync Configuration
The
Time Sync Configuration
page allows selection of the source to be used for
synchronizing flows, and configuration of any properties associated with the relevant
source.
Fig. 4-5: Time Sync Configuration Page
Domain
R uses domains to partition a network; only nodes on the
same domain can communicate with one another. A domain is
uniquely identified with a number and a friendly name/alias.
Set an ID as required, then press
Take
to confirm the change.
Interface Configuration
Displays the IP address for each of the Ethernet interfaces.
Ethernet 1
represents the IPVU’s
MEDIA 1
connection,
Ethernet
2
represents the IPVU’s
MEDIA 2
connection, and
Ethernet Gb
represents the IPVU’s
MANAGEMENT
connection. See
Connections, Reset Pushbutton, and Status Indicators
Card Firmware/Software
Version
Each software version contains multiple firmware images. These
allow different spigot input/output and flow standard
combinations to be selected.
Select the required software from the
Software Version
pane, then
select the firmware which provides the required combination of
inputs, outputs and flow standards from the list displayed on the
Firmware
pane.
Note
:
Restore
and
Restart
buttons are displayed
only when an item not currently installed is selected.
Click
Take
to restart the IPVU and implement any changes made.
Option
Operation
Содержание Grass Valley IPVU
Страница 1: ...Installation Guide 13 03068 010 M00 AA 2019 07 22 IPVU Compact IP Monitoring Gateway...
Страница 16: ...16 Table of Contents...
Страница 32: ...32 Connections and Cabling Locking Monitor Outputs...
Страница 94: ...94 Specifications Compliance...