HDA-3911/-3931 

Single/Dual 3G-HD-SD SDI Distribution Amplifiers 

 

 

 

 

 

 

 

 

 

Guide to Installation and Operation 

 

M3056-9900-100 

 

2015-08-21 

 

  

Содержание GRASS VALLEY HDA-3911

Страница 1: ...HDA 3911 3931 Single Dual 3G HD SD SDI Distribution Amplifiers Guide to Installation and Operation M3056 9900 100 2015 08 21 ...

Страница 2: ...manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense This equipment has been tested and found to comply with the requirements of the EMC directive 2004 108 CE EN 55022 Class A radiated and conducted emissions ENV 5...

Страница 3: ... 3 2 Card Edge Status LED 7 3 3 Local control using the Densité 3 frame control panel 8 3 3 1 Overview 8 3 3 2 Menu for local control 8 3 4 Remote control using iControl 9 3 4 1 The iControl graphic interface window 9 3 4 2 The Input panel 11 3 4 3 The Rear panel 12 3 4 4 The Status panel 12 3 4 5 The Output panel 13 3 4 6 The Alarms panel 13 3 4 7 The Info panel 16 3 4 8 The Presets panel 17 4 Sp...

Страница 4: ...GUIDE TO INSTALLATION AND OPERATION HDA 3911 31 ...

Страница 5: ... are required the HDA 3911 3931 are ideal since they can natively offer fiber connectivity Additional protection for critical applications is provided by an optional protection bypass relay available on selected rears The HDA 3911 3931 will also support DVB ASI on selected outputs 1 2 Features One HDA 3911 or two HDA 3931 inputs Up to nine 3GHD SD SDI outputs Supports bit rates all the way up to 2...

Страница 6: ...31 Functional Block Diagram 1 4 Front Card edge Interface The front card edge of the HDA 3911 31 incorporates two elements Status LED see section 3 2 Select Button see section 3 3 Select Button IRD 3802 Status LED Status Select HDA 3911 Figure 1 2 Front card edge layout ...

Страница 7: ...support For the HDA 3931 HDA 393N 3SRP Single rear for dual 1x3 operating mode HDA 393N 3SRP F Single rear for dual 1x3 operating mode with fiber option support HDA 393N 3DRP Double rear for dual 1x4 operating mode All cards and rear panels can be installed with the frame power on The card has connectors which plug into a mid frame mother board for distribution of power and for connection to the c...

Страница 8: ...e the HDA 39x1 card into the slot and push gently on the handle to seat the connectors If the card is used with a double width rear panel 3DRP it should be inserted into the right hand slot Inserting the card into the wrong slot will not damage the card and will be flagged by the on card status LED flashing red to indicate that there is no connection to the rear panel 3 Close the front panel of th...

Страница 9: ...ons on the various rear panels shown above I O Connections Use with Rear panel type 3G HD SD SDI IN 3G HD SD SDI OUT FIBER I O Bypass HDA 3911 HDA 3931 HDA 391N 3SRP 1 7 HDA 391N 3SRP R 1 7 HDA 391N 3SRP F 1 5 HDA 393N 3SRP 2 2 x 3 HDA 393N 3SRP F 2 2 x 3 HDA 393N 3DRP 2 2 x 4 Note that the HDA 393N 3SRP F panel uses DIN1 0 2 3 connectors on outputs A2 A3 and B2 B3 All other electrical connectors ...

Страница 10: ...ber I O connector accepts any of the available SFP cartridges At the time of publication of this document the following cartridges were available SFP R LC Single fiber Rx input cartridge with LC PC connector SFP RR LC Dual fiber Rx input cartridge with LC PC connector SFP T S13 LC Single fiber Tx output cartridge at 1310 nm with LC PC connector SFP TT S13S13 LC Dual fiber Tx output cartridge at 13...

Страница 11: ...ous error conditions that can be flagged on the HDA 39x1 affect the LED status If a cell is gray the error condition cannot cause the LED to assume that status If more than one LED status is possible for a particular error condition the status is configurable See Section 3 4 6 for details The factory default status is shown by a The LED will always show the most severe detected error status that i...

Страница 12: ...d card flashes yellow The local control panel displays a menu that can be navigated using the four pushbuttons located beside the display The functionality of the pushbuttons is as follows Used for menu navigation and value modification SELECT Gives access to the next menu level When a parameter value is shown pushing this button once enables modification of the value using the and buttons a secon...

Страница 13: ...igure 3 2 The window identification line gives the card type HDA 3911 or HDA 3931 and the slot number where the card is installed in its Densité frame Figure 3 2 HDA 3931 iControl graphic interface window There are three main sections in the window itself shown in Figure 3 2 1 The top section displays icons on the left These icons report the status of some parameters associated with this HDA 39x1 ...

Страница 14: ...rface will have no effect on the card Icon 2 Input A status green Signal detected and valid Beneath the icon the format will be indicated as 3G HD or SD and the specific format details will be listed if the cursor is moved over the icon red Input signal error No rear grey No electrical input Icon 3 Input B status only on HDA 3911 green Signal detected and valid Beneath the icon the format will be ...

Страница 15: ...HDA 39x1 HDA 3911 Only one channel is available so channel B does not appear in the panel HDA 3931 Two channels are available The rear panel may have one or two electrical inputs and may have two optical inputs Channel B will be greyed out if no signal is available for it Input Config Select the input for Channel A and Channel B using the radio buttons Electrical Input A and Optical Input A can on...

Страница 16: ...status of the various inputs to this HDA 39x1 For HDA 3911 only IN A is shown because there is no IN B Electrical inputs A and B Data rate 270 Mbps 1 5 Gbps 3 Gbps the detected input data rate is indicated by a green status icon No Lock No Signal either of these conditions is indicated by a red status icon Fiber Module type the type of fiber module installed in the rear panel will be shown in the ...

Страница 17: ...ector and an installed output TX cartridge Optical output A if available can only carry channel A Optical output B if available can carry either Channel A or Channel B on an HDA 3931 and the choice is made here On an HDA 3911 only channel A is available because there is no channel B 3 4 6 The Alarms panel This panel allows the alarm reporting of the HDA 39x1 to be configured Click on the Alarm Con...

Страница 18: ...Alarm Status associated with this card GSM is a dynamic register of all iControl system alarms and is also an alarm provider for external applications The possible values for this contribution are related to the Overall alarm contribution If the Overall alarm contribution is selected as Disabled the GSM alarm contribution can be set to any available value If the Overall alarm contribution is selec...

Страница 19: ...o open a save dialog where you can save a file containing a list of all alarms on this card and their current values along with an Alarm Key for each The alarm keys are useful for system integration and troubleshooting The file is saved in csv format OK Apply Cancel OK accepts the settings and closes the window once the card confirms that there are no errors Apply accepts the settings but leaves t...

Страница 20: ...n for this HDA 39x1 when it appears in iControl applications Short Label type the short form label that iControl uses in some cases 8 characters Source ID type a descriptive name for this HDA 39x1 Comments type any desired text The remaining data boxes show manufacturing information about this card Three buttons in the panel give access to other information Details Reports the Firmware version ser...

Страница 21: ...om the window You will be asked to confirm the removal in a Query box 3 4 8 The Presets panel User Presets The HDA 39x1 has memory registers which can hold up to 5 user defined parameter settings Select any one of the five presets using the pull down list The name of the currently selected User Preset is shown on the name bar Click Load to load the contents of the selected User Preset into the HDA...

Страница 22: ... 2967 2970Mb s EN50 83 9 DVI ASI 270 Mbps Cable length 15km of SMF fiber 9 125 at wavelengths between 1260nm and 1600nm ELECTRICALOUTPUTS 9 Signal 3G HD SD SDI SMPTE 424M 292M and 259M C compliant Supports data rates of 270 1483 5 1485 2967 2970Mb s EN50 83 9 DVI ASI 270 Mbps 5 outputs only Return loss 15 dB for up to 1 5GHz 10 dB from 1 5GHz to 3GHz Jitter wideband 0 2 UI p p Rise Fall time 135 p...

Страница 23: ... or 1 530 478 4148 To obtain a local phone number for the support center nearest you please consult the Contact Us section of Grass Valley s website www grassvalley com An online form for e mail contact is also available from the website Corporate Head Office Grass Valley 3499 Douglas B Floreani St Laurent Quebec H4S 2C6 Canada Telephone 1 514 333 1772 Fax 1 514 333 9828 www grassvalley com ...

Страница 24: ...TX FIBER RX A TX B FIBER IN A NO LOCK NO SIGNAL 270 Mbps 1 5 Gbps 3 Gbps INPUT CONFIG INPUT A ELECTRICAL A OPTICAL A OUTPUT CONFIG OPTICAL A ON OFF OPTICAL B ON OFF RECLOCKER RECLOCKER A ON BYPASS USER PRESET LOAD USER 1 USER 2 USER 3 USER 4 USER 5 SAVE USER 1 USER 2 USER 3 USER 4 USER 5 CONFIG ALARMS CH A NO LOCK ALARM LEVEL GREEN YELLOW RED FLASH RED ALARM REPORT NONE GPI CH A NO SIGNAL ALARM LE...

Страница 25: ...B INPUT B ELECTRICAL B OPTICAL B OUTPUT CONFIG OPTICAL A OFF ON OPTICAL B OFF ON RECLOCKER RECLOCKER A ON BYPASS RECLOCKER B ON BYPASS OPERATING MODE DUAL CHANNEL SINGLE CHANNEL USER PRESET LOAD USER 1 USER 2 USER 3 USER 4 USER 5 SAVE USER 1 USER 2 USER 3 USER 4 USER 5 CONFIG ALARMS CH A NO LOCK ALARM LEVEL GREEN YELLOW RED FLASH RED ALARM REPORT NONE GPI CH A NO SIGNAL ALARM LEVEL GREEN YELLOW RE...

Страница 26: ... it is installed DO NOT LOOK INTO AN OPERATING SFP MODULE S CONNECTORS AS EYE DAMAGE MAY RESULT The SFP module is sensitive to electrostatic discharge ESD It is recommended that you use an ESD preventive wrist strap grounded to the Densité 3 chassis while handling the SFP module SFP modules are subject to wear and their useful lifetime is reduced each time they are inserted or removed Do not remov...

Страница 27: ...1 Grasp the LC fiber optic connector that is plugged into the SFP module and pull it straight out to disengage the optical fiber from the SFP Never pull the fiber optic cable itself as catastrophic damage may occur 2 Insert a dust plug into the SFP module Removing the SFP module 1 Move the latch to the open position 2 Grasp the SFP module between your thumb and forefinger and pull it straight out ...