The EC9535 GSC Node Bus Converter is a communications protocol converter that allows 
Miranda’s NV8288, NV8288-Plus and NV8500 family routers to communicate with an SMS7000 
router control system.

A router must have (1) a GSC Node Bus connector and (2) a control card that follows the 
SMS7000 protocol. The NV8288, NV8288-Plus and the NV8500 family routers do not have these 
items. 

The EC9535 has the GSC Node Bus connector and the control cards that follow the SMS7000 
protocol. The SMS7000 connects to the EC9535, which in turn, connects to the router: 

The EC9535 interprets commands from the SM7000, sending equivalent commands to the 
router. It also interprets status mesages from the router, returning their equivalent to the 
SMS7000.

Product Overview

The EC9535 GSC Node Bus Converter is used as an interface between a SMS7000 system 
controller and a specific Grass Valley router. Unlike a router, the EC9535 does not actively 
manage signals. Instead the EC9535 provides a GSC Node Bus to serial interface that enables a 
SMS7000 system controller to communicate wit h Miranda routers that feature only serial 
system controller connections. In addition, the EC9535 provides high reliability through redun-
dant power supplies and redundant control cards, as well as deterministic communications 
processing.

Mounting

The EC9535 GSC Node Bus Converter mounts in a rack with minimum dimensions of 2RU high 
(3.47 inches, 88.1 mm), and 16.0 inches (406 mm) deep. When placing the rack in your facility, be 
sure to leave enough space for air flow through the front and rear of the EC9535 and within easy 
access of an AC power source. For mounting instructions, see 

Rack Mount

 on page 10.

Fuses

The EC9535 GSC Node Bus Converter has no user-serviceable fuses.

SMS7000

EC9535

Router

command

status

command

status

Содержание Grass Valley EC9535

Страница 1: ...EC9535 GSC Node Bus Converter Reference Manual UG0050 01 26 Nov 2014...

Страница 2: ...routers to use their product manuals for their own internal business use Manuals for Grass Valley products may not be reproduced or transmitted in any form or by any means electronic or mechanical inc...

Страница 3: ...ards are marked as required by law with the CE mark When shipped into member countries of the European Community this equipment is accompanied by authentic copies of original Declarations of Conforman...

Страница 4: ...symbol within an equilateral triangle alerts the user to the presence of dangerous voltages within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to...

Страница 5: ...xplosion do not operate this equipment in an explosive atmosphere Have qualified service personnel perform safety checks after any service General Cautions A caution indicates a possible hazard to equ...

Страница 6: ...vi...

Страница 7: ...k Mount the EC9535 10 Installing Control Cards 10 How to install control cards 11 Making System Controller Connections 11 How to Make SMS7000 System Controller Connections 11 Making Router Connections...

Страница 8: ...nt 21 Air Flow 22 Obtaining Service 22 5 Technical Details 23 Power Specifications 23 Mechanical Specifications 23 Environmental Specifications 24 Audio Specifications 24 Video Specifications 24 Time...

Страница 9: ...ed as an interface between a SMS7000 system controller and a specific Grass Valley router Unlike a router the EC9535 does not actively manage signals Instead the EC9535 provides a GSC Node Bus to seri...

Страница 10: ...r features a single door When facing the front of the frame the right hand side features an open grill through which a fan draws cooling air A handle is provided on the left hand side The door is hing...

Страница 11: ...nections The rear of the EC9535 frame features a back plate containing several connections for managing system functions and two power connections Fig 1 3 EC9535 Rear View These connections enable you...

Страница 12: ...is provided for future flexibility For installation instructions see Making Router Connections on page 12 Fig 1 5 Serial Control Connections Rear View Diagnostic Connections The diagnostic connection...

Страница 13: ...address is set using UniConfig However UniConfig runs on a PC and cannot communicate with EC9535 until an IP address has been entered Therefore you must use a serial connection the DIAG port s to com...

Страница 14: ...itch point The video reference connections require a stable source of PAL NTSC or Tri level sync This reference is not currently used but provided for future flexibility For more information contact T...

Страница 15: ...when an alarm is activated Creation of an external alarm indicator is outside the scope of this manual however basic instructions on wiring the alarm connection for external monitoring is provided See...

Страница 16: ...8 Introduction Rear Connections...

Страница 17: ...ant when initially configuring the router and any time the router is reconfigured See Making Diagnostic Connections on page 13 5 Connect the alarm connection on the router to an external indicator See...

Страница 18: ...airflow for frame cooling Installing Control Cards The EC9535 comes with two control cards EM0374 already installed Each control card has a mezzanine SM0220 designed to communicate with the SMS7000 c...

Страница 19: ...s or NV8500 Family router to communicate the system controller must be connected to an EC9535 The SMS7000 system controller is connected using the GSC NODE BUS connection located on the rear of the EC...

Страница 20: ...on each end for a total of four DE9 connectors The serial control ports are divided into two sets that enable the primary control card or the secondary control card in the EC9535 frame to communicate...

Страница 21: ...using UniConfig see the UniConfig User s Guide There are two sets of diagnostic connections one set is located on the front of the control cards and one set is located on the rear of the EC9535 labele...

Страница 22: ...tions on the rear of the EC9535 as shown in Figure 2 5 The diagnostic connections are labeled DIAG Fig 2 5 Diagnostic Connections Rear View 2 Connect to the DIAG connection in the PRI section using a...

Страница 23: ...rear of the router locate the ALARMS connector Fig 2 6 System Alarm Connection Rear View 2 Connect to the ALARMS connection using a DE9 connector and cable 3 Connect the other end of the cable to an e...

Страница 24: ...uring alarm condition External Power 30VDC max 150mA max Normally ON the LEDs turn off to indicate failure 1 COM Normally OFF the LEDs turn on to indicate failure 30VDC max 150mA max External Power 1...

Страница 25: ...4 Repeat step 2 and step 3 for the PS2 48V connection 5 Connect the EC9535 s ground lug to earth ground using a copper wire from 14 to 6 AWG The ground lug is located in the lower right corner of the...

Страница 26: ...18 Installation Connecting to Power...

Страница 27: ...d router s CTRL 1 serial port rate See Serial Control Connections on page 4 By default the NV8288 NV8288 Plus and NV8500 Family routers have the CTRL 1 ports set to 38 400 baud However the number of d...

Страница 28: ...20 Configuration...

Страница 29: ...our fingers and pull it towards you to remove it Call Grass Valley for replacement battery information For contact information see Grass Valley Technical Support on page 35 Only qualified service pers...

Страница 30: ...replacement information For out of warranty equipment the Grass Valley Technical Support Engineer estimates the cost of repair when you call and requests a purchase order payable to Grass Valley If r...

Страница 31: ...inches 406mm deep Weight 22 lbs 9 97 kilograms Mounting EIA 310 C 19 0 inches 483 mm Grounding terminal Copper accepts 14 6 AWG Modules and slots 2 Control cards 1 primary 1 optional secondary Diagnos...

Страница 32: ...tandard AES3id Sample Rate 48kHz Connector 2 BNC redundant Impedance 75 Input Level 0 5Vpp to 2 0Vpp Type Parameter Video Reference Input Type Analog video reference Standard PAL NTSC or tri level syn...

Страница 33: ...d by Grass Valley for the EC9535 Part Number Description PS0007 AC to 48V DC Power supply EM0374 Control card SM0220 Mezzanine on control card for SMS7000 system controllers WC0152 Proprietary router...

Страница 34: ...26 Part Numbers...

Страница 35: ...n an NV5128 frame AVC coding provides a cost effective method to provide feeds to picture monitors without requiring an external conversion device AVC modules are not a substitute for professional gra...

Страница 36: ...ice s signal set Physically Contiguous Matrix modules are said to be in physically contiguous slots in a EC9535 frame when both the inputs and outputs associated with those slots are in numerical sequ...

Страница 37: ...locked include common SD data rates of 143 and 270Mb s SMPTE 259M A and C but not B or D and HD data rates at nomi nally 1 485Gb s SWB accepts SD at 177Mb s but does not reclock it Sync AES Async AES...

Страница 38: ...30 Glossary...

Страница 39: ...PC 10 Configuring 19 Connecting power 2 16 Connector DB9 10 RJ 45 10 Connectors AES reference 5 BNC 27 DB25 27 DE9 27 Diagnostic 4 Ethernet 5 GSC Node Bus 3 Power 16 RJ45 RJ 45 28 Serial control 4 Sy...

Страница 40: ...preparing for 10 IP address about 5 L LEDs About 21 Level physical 28 License iii M Maintenance 21 Matrix defined 28 MCPM RS 232 port 10 Middle East contact 35 Miranda contact 35 Module defined 28 Mo...

Страница 41: ...S7000 system controller connections 3 Software license iii Source defined 28 Specifications power supply 23 Specifications router 23 Steps for installation 9 Steps for reconfiguration 9 Support contac...

Страница 42: ...34 Index...

Страница 43: ...4 118 952 3401 E mail eurotech grass valley com Playout Automation Europe Middle East Africa UK Office hours 9 00 a m 5 30 p m GMT Telephone 44 870 500 4350 Fax 44 870 500 4333 automationsupport grass...

Страница 44: ......

Отзывы: