background image

Installation and User Guide

MADI-SWITCH

8x1 MADI SOURCE SELECTOR

MS64-F, MS64-C, MS64-FC

SEL

PSU

MADI-SWITCH

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

OUT

IN

SIG SEL

SIG SEL

SIG SEL

SIG SEL

SIG SEL

SIG SEL

SIG SEL

SIG SEL

MS64-C

SWITCH

MADI

DIGITAL GROUP

Содержание MS64-C

Страница 1: ...Installation and User Guide MADI SWITCH 8x1 MADI SOURCE SELECTOR MS64 F MS64 C MS64 FC SEL PSU OUT IN OUT IN OUT IN SIG SEL SIG SEL SIG SEL MS64 C SWITCH MADI ...

Страница 2: ...cled in a manner that protects human health and the environment For more information about where you can drop off your waste equipment for recycling please contact your local city office your household waste disposal service or where you purchased the product User s Notice and disclaimer No part of this manual may be reproduced transmitted transcribed stored in a database system or translated with...

Страница 3: ...rtant Safety Information 5 Introduction 6 What s In The Box 6 MADI SWITCH Main Features 6 Front Panel Description 7 Rear Panel Description 8 Installation 9 Hardware Considerations 9 Power Supply Considerations 9 Fuses And Ratings 9 Unit Connections 9 Operation 10 Connection 10 Source Selection 10 Example Connection Diagram 11 Technical Specifications 12 Contents ...

Страница 4: ...pparatus There are no user replaceable fuses 19 An external over current protection device is required to protect the wiring to this apparatus This protection device must be installed according to current wiring regulations In certain countries this function is supplied by use of a fused plug 20 If an extension power cable or adaptor is used ensure that the total power rating of the power cable an...

Страница 5: ...RE SERVICING The lightning flash with arrowhead symbol within equilateral triangle is intended to alert the user to the presence of uninsulated dangerous voltage within the product s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons The exclamation point within an equilateral triangle is intended to alert the user to the presence of important operating...

Страница 6: ...ADI sources to be labelled for clarity and ease of operation The MADI SWITCH is a very high quality product engineered for maximum reliability in professional broadcast live and production environments It requires virtually no configuration on installation or adjustment in normal use This manual covers the MADI SWITCH s connections and indications Please keep the manual in a safe place once you ha...

Страница 7: ...depends on model BNC 75 ohm or Fibre multimode as standard OUT Active MADI loop through connector Connector type depends on model BNC 75 ohm or Fibre multimode as standard SIG LED indication of active source being connected to the MADI input connector SEL LED used to indicate which MADI source is routed to the rear panel fibre and coaxial MADI outputs Scribble Strip traditional scribble strip to l...

Страница 8: ...n COAX OUT Coaxial MADI output BNC derived from the selected front panel MADI source FIBRE OUT Optical fibre MADI output SC derived from the selected front panel MADI source multimode as standard PSU 1 AC input IEC Socket PSU 2 AC input IEC Socket OUT OUT COAX FIBRE Not Used MADI ...

Страница 9: ... of the MADI SWITCH s PSUs has an internal resettable fuse for PSU protection These fuses are not accessible to the user The unit should be powered from a mains supply supplies fitted with an external HRC type fuse High Inrush Current rated at 1 A Installation Unit Connections MADI Inputs and Outputs MADI inputs are provided as either fibre on an SC type connector multimode as standard coaxial on ...

Страница 10: ...DI outputs The SEL switch has a momentary action when pushed down which advances the port selection The active port is indicated by the illumination of the SEL LED located adjacent to each front panel port Also on the front panel again located by each port is an LED marked SIG This LED illuminates if the input is connected and active at the source for example the transmitter end of the fibre It is...

Страница 11: ...MADI OUTPUT OPTICAL MADI OUTPUT MADI STREAM 1 INPUT LOOP THROUGH MADI STREAM 8 INPUT LOOP THROUGH MADI STREAM 2 MADI STREAM 3 MADI STREAM 4 MADI STREAM 5 MADI STREAM 6 MADI STREAM 7 Example Connection Diagram Connection example based on the MS64 F Similar principle applies to the MS64 C and MS64 FC ...

Страница 12: ...x SC socket multi mode and 4 x BNC for MS64 FC Output 1 x SC socket multi mode 1 x BNC Data Rate 125 Mbps 25ppm accepts any data format Sampling frequency 44 1 kHz to 384 kHz POWER SUPPLY Type 2 x independent switch mode regulated auto ranging Inputs 2 x 90 to 264 V AC 50 60 Hz Power consumption 16 W Connectors 2 x IEC with retaining clips PHYSICAL Dimensions w x d x h 483 x 249 x 45 mm 19 x 10 x ...

Страница 13: ...Bel Digital Audio Limited 3 Horwood Court Bletchley Milton Keynes MK1 1RD United Kingdom Tel 44 0 1908 641063 Email info beldigital com URL www beldigital com ...