10.3.5 Cleaning
CAUTION
Inappropriate cleaning and use of the wrong cleaning media!
Inappropriate cleaning and the use of the wrong cleaning media may result in minor injuries
as well as damage to health and damage to property.
• Never clean the device with a dripping wet cloth.
• Never use abrasive or aggressive cleaning agent or solvents which could damage the
outer coating (e.g. markings, type plate, corrosion protection, etc.).
• Never clean the device with hard or pointed implements.
• Use an anti-static, damp cloth for cleaning the outside.
• Immediately replace any product markings (pictograms, markings) that have become
illegible.
NOTE
Local hygiene regulations!
In addition to the cleaning instructions listed, any regionally applicable hygiene regulations
must be observed.
Prerequisites
Tools
Material
Protective equipment
• Cleaning brush
• Mild cleaning agent
• Cotton or disposable cloth
Always to be worn:
Preparatory tasks
1.
Decommissioning and disassembly of the
BEKOMAT
®
have been completed.
2.
The
BEKOMAT
®
is disassembled.
Cleaning work
Illustration
Description / explanation
1. Spray mild cleaning agent onto a cotton cloth or
disposable tissue until it is damp (not wet). Rub the
surfaces of the
BEKOMAT
®
with a damp cloth.
2. Clean the control-air bore and the condensate
discharge bore using a cleaning brush Ø max. = 2.5 mm
(0.09").
BEKOMAT
®
13i / 13i CO / 13i CO PN50
Original installation and operation manual
58 | 76
Содержание BEKOMAT BM13i
Страница 73: ...Original installation and operation manual BEKOMAT 13i 13i CO 13i CO PN50 73 76 ...
Страница 74: ...16 2 Declaration of Conformity BEKOMAT 13i 13i CO 13i CO PN50 Original installation and operation manual 74 76 ...
Страница 75: ...Original installation and operation manual BEKOMAT 13i 13i CO 13i CO PN50 75 76 ...