4. Technical data
4.1 Operating parameters
BEKOMAT
®
13
13 CO
13 CO PN25
13 CO PN40
Min. / max. operating pressure
0.8 ... 16 bar(g)
12 ... 230 psi(g)
1.2 ... 25 bar(g)
18 ... 362 psi(g)
1.2 ... 40 bar(g)
18 ... 580 psi(g)
Min./max. operating temperature
+1 … +60 °C
+34 … +140 °F
Min./max. ambient temperature:
+1 … +60 °C
+34 … +140 °F
Min./max. ambient air humidity
10 ... 80 %, non-condensing
Condensate inlet
2 x G1/2 (internal thread)
2 x 1/2" NPT (internal thread)
Condensate discharge
G1/2 (internal thread)
G3/8 (internal thread)
Media
Condensate, oil-
contaminated
Condensate, oil-contam oil-free
Empty weight
2.0 kg
4.4 lbs
2.2 kg
4.8 lbs
Operating voltage
230 / 115 / … / 24 VAC ± 10%, 50 … 60 Hz / 24 VDC ± 10%
See type plate
Power consumption
P < 8.0 VA (W)
Fuse protection
recommended for AC: 1 A (time-lag) | prescribed for DC: 1 A (time-lag)
Recommended cable diameter
5.8 ... 8.5 mm
0.23 … 0.34 inch
Recommended wire cross-section
(voltage supply)
3 x 0.75 … 1.5 mm²
AWG 16 ... 18
Recommended shortening of the
cable jacket
PE= ~ 60 mm
~ 2.3 inch
L|N= ~ 50 mm
~ 1.96 inch
Recommended stripping length of
the cable wires
~ 6 mm
~ 0.24 inch
Connection data potential-free
contact for switching load
AC: max. 250 V / 1A | DC: max. 30 V / 1A
Degree of protection
IP65 / NEMA 13
Overvoltage category
II
Degree of pollution
3
BEKOMAT
®
13, 13 CO, 13 CO PN25, 13 CO PN40
Original installation and operation manual