Air conditioner / User Manual
23 / 64 EN
•
Decide whether to saw the unloading piece off in accordance with the piping direction. (as shown
below)
1
2
3
4
Piping direction
trough
Unloading
piece
Saw the unloading piece
off along the trough
C
Note:
When installing the pipe at the directions 1, 2 or 4, saw the corresponding unloading
piece off the indoor unit base.
•
After connecting the piping, install the drain hose. Then connect the power cords. After connecting,
wrap the piping, cords and drain hose together with thermal insulation materials.
•
Piping joints thermal insulation:
Wrap the piping joints with thermal insulation materials and then wrap with a vinyl tape.
Thermal insulation
wrapped with vinyl type
•
Piping thermal insulation:
1. Place the drain hose under the piping.
2. Insulation material uses polythene foam over 6mm in thickness.
C
Note:
Drain hose is prepared by user.
•
Do not arrange the drain pipe in a way that leaves it twisted, sticking out or waving around. Do not
immerse the end of it in water.
•
If an extension drain hose is connected to the drain pipe, make sure to insulated when passing along the
indoor unit.
8
Installation instructions