Troubleshooting Guide
Issue
description
Troubleshooting
Suggested solution
Handpiece
does not start
Power cord is disconnected
Reconnect and ensure the
cord is secure
Switch is not responsive
Replace switch
Wire broken to the switch
Reconnect
Control board issue
Replacement
Handpiece
overheating
First, find out accurately which part of the handpiece is overheating. Do
this by restarting the handpiece after letting it cool down.
Front portion
overheating
May be due to build-up of dust or debris
in the front portion of the handpiece.
Start the handpiece whilst
pressing and sealing the oil
hole with your thumb, fill in
oil from the front of the
handpiece into the body,
then flip the handpiece and
drain thoroughly.
Check to see if the comb and cutter are
sharp, and proper tension was applied
Re-grind the comb and
cutter, lessen tension
pressure
Thumb and
index finger
portion
overheating
Check the center post and center post
nut, ensure there is no foreign object in-
between
Lift the crank spindle, flush
out the foreign object with
lubricant
Check for signs of wear on the center
post or center post nut
Replace with new parts
Tension nut
overheating
Check the tension pin and tension pin
cup, ensure there is no foreign object in-
between
Remove dust and debris,
apply new grease
Check for signs of wear on the tension
pin or tension pin cup
Replace with new parts
Middle finger
or ring finger
portion
overheating
Check to see if the roller is installed
correctly (make sure the flat side is
facing the crank spindle)
Reinstall the roller
May be due to wool getting caught in the
roller
Remove the wool
A lack of lubrication for cogs in gearbox
Apply lubrication