Beijer Electronics Fax 801-466-8792 Web www.beijerelectronicsinc.com Phone 801-466-8770
A
PPENDIX
C.
QTERM C
OMMAND
S
UMMARY
This appendix is an abbreviated summary of all of the
available QTERM software commands. More detailed
descriptions of the commands are in Chapter 2.
Refer to Table 1-2 for a complete list of acceptable parame-
ter values for applicable commands. If a command parame-
ter is out of the valid range, the QTERM ignores the entire
command.
Note that the timing shown for the execution of the various
commands is only approximate. Many factors can affect the
execution time, so it is impossible to give exact figures.
Command
String
Timing
(ms)
Notes & Parameters
display character
0.7
14.0
37.0
typical in replace mode
typical in insert mode
worst case in insert mode
Bell (^G)
07H
0.6
other buzzer commands not executed until beep is over
Backspace (^H)
08H
0.8
Horizontal Tab (^I)
09H
0.8
1.1 ms worst case
Line Feed (^J)
0AH
0.8
up to 35 ms if auto scroll is on
Vertical Tab (^K)
0BH
same as line feed
Form Feed (^L)
0CH
same as line feed
Carriage Return (^M)
0DH
0.8
up to 35 ms if auto scroll is on
XON (^Q)
11H
0.4
XOFF (^S)
13H
0.4
Delete
7FH
1.2
Cursor Up
]
A
0.8
Cursor Down
]
B
0.8
Cursor Right
]
C
0.8
Cursor Left
]
D
0.8
Clear Screen
]
E
4.4
Set Timeout Delay
]
F#
1.2
see Table 1-2
Set Tab Spacing
]
G#
1.2
#= @ causes tabs to be ignored
A to S for tab set every 1 to 19 spaces
Cursor Home
]
H
3.7