Beijer Electronics Frequency Inverter BFI-E3
KI00369C 2021-09
www.beijer.se www.beijer.no
www.beijerelectronics.de www.beijerelectronics.com www.beijerelektronik.com.tr
4 (28)
4.2 Physical dimensions IP66
BFI-E3- -IP66
Drive
size
A
Height
[mm]
B
Width
[mm]
C
Depth
[mm]
D
[mm]
E
[mm]
Weight
[kg]
1 x 230 V
3x200-240 V
3x380-480 V
0023-0070
[0,37-1,5 kW]
Does not exist
0022-0041
[0,75-1,5 kW]
1
232
161
162
189
149
2,5
0070- 0105
[1,5-2,2 kW]
0070- 0105
[1,5-2,2 kW]
0041-0095
[1,5-4,0 kW]
2
257
188
182
200
178
3,5
0153
[4,0 kW]
0180-0240
[4,0-5,5 kW]
0140-0240
[5,5-11 kW]
3
310
210
238
252
197
7,0
Does not exist
0300-0460
[7,5-11 kW]
0300-0460
[15-22 kW]
4
360
240
275
300
227
9,5
NOTE
1x230 BFI-E3-0070 and 3x400 V BFI-E3-0041 are without brake transistor for Size 1-2ize2 with.
Mounting bolts
All Frame Sizes: 4xM4
Control Terminal, Required Torque
All Frame Sizes: 0,5 Nm.
Power Terminal, Required Torque
Size 1-3 = 0,8 Nm, Size 4= 2 Nm.
IP66 drives are fitted with a movable gland plate containing two cable entry holes. Please
take care when drilling to avoid any particles within the BFI.
Holes and recommended glands are listed in table below.
Cable Gland, IP66 Hole Size & recommended glands
Frame size
Hole sizes
Recommended PG Gland
Size 1
2 x 22 mm
PG16 (correspond to M20)
Size 2 & 3
2 x 27 mm
PG21 (correspond to M25)
Size 4
2 x 37 mm
PG29