5.4 Digital start signal and frequency set point by LED display
Connect terminal 2 with terminal 1 to give digital start signal forward and terminal 3 to 1 for
digital start signal reverse.
Output frequency can be increased and decreased by push button ”Up” and ”Down”. In
parameter P-31 the start speed can be decided either latest speed or minimum speed.
Para-
meter
Name
Default
settng
To be set
Function
P-12
Primary Command
0
1
Start by connecting terminal 1 and 2.
P-15
Digital Input function
selection
0
8
8: Start signal forward on terminal 2 och start signal reverse on
terminal 3. If both terminal 2 and 3 are on deceleration time in P-
24 is used.
P-30
Terminal restart mode
: Startsignal on terminal 2 is activated by positive edge.
After power on must terminal go from 0 VDC to 24 VDC.
= Jumper between 1 and 2 or 1 to 3 starts aleays the
motor.
P-31
Keypad function
1
2: Motor accelerete to minimal frequency, P-02, at start.
3: Motor accelerete to latest speed before stop.
5.5 Start/stop by individual signals
Start is done by a pulse on one terminal and stop on a second one. Third input decides if
frequency set point is to be analogue or a PresetSpeed in P-20. If 4-20 mA signals are to be used
current must enter terminal 6 and back from terminal 7.
5.6 Control from LED display
Connect terminal 2 with terminal 1 to give digital start signal. Then set parameters as below:
Para-
meter
Name
Default
settng
To be set
Function
P-12
Primary Command
0
Start activated by green start button and stop by red Stop button.
Speed is increased by ”Up-button” and decreased by ”Down-
button”.
1: Motor can only run in one direction.
2: Motor can run in two directions. Rotation direction is changed
by pushing green start button twice.
P-31
Keypad function
1
0: Motor accelerete to minimal frequency, P-02, at start.
1: Motor accelerete to latest speed before stop.
Status
Action
DI1 DI2 DI3
P12 = 0 and P15=10
-
0
-
No output from drive or deceleration to 0 Hz.
1 ↑
1
0
Running with analogue frequecy set point.
1 ↑
1
1
Running with PresetSpeed 1 in P-20.
DI2:
Stop
2
3
5
6
7
1
DI1:
Start pulse
DI3:
Preset speed1
0 VDC
+24 VDC
Analog reference
+10 VDC
4-20
mA
4